Nortel Business Communications Manager 450 1.0
Installation — System
NN40160-301 01.04 Standard
July 2009
Copyright © 2006-2009 Nortel Networks
BCM450 common procedures
This chapter describes common procedures for the BCM450 system.
BCM450 common procedures navigation
•
Rebooting the BCM450 (page 95)
•
•
Installation troubleshooting (page 96)
Rebooting the BCM450
You can reboot the BCM450 system through Element Manager. For
information to install Element Manager, see
Prerequisites
•
Element Manager must be installed on a PC connected to the BCM450
system, either through the LAN, soft modem, ISDN, or directly through the
OAM port.
Step
Action
1
Check for a recent backup of the BCM450 system programming.
2
If no recent backup is available, use Element Manager to back up the
system data. For information about backing up the system data, see
Nortel
Business Communication Manager 450 1.0—Administration and Security
(NN40160-601).
3
From the
Administration
tab, click the
Utilities
folder to expand it.
4
From the
Utilities
folder, select
Reset
.
5
Click
Reboot BCM450 System
to reboot the system.
--End--