Nortel BayStack 410-24T Скачать руководство пользователя страница 2

BayStack 410 and 450 Switches Data Sheet

2

Figure 1:   In the unlikely event 

of a switch failure, 
the stack integrity 
is maintained: cascade
signals loop back at
point of failure.

Table 1:  Port, MDA, and Stacking Module Slot Configurations

of the BayStack 410 and 450 Switches.

Autosensing 

Cascade

10BASE-T/ 

Stacking

100BASE-TX 

MDA

Module 

BayStack Switches

Ports

Slot

Slot

BayStack 450-12T

12

1

1

BayStack 450-24T

24

1

1

Baystack 410-24T

24 (10BASE-T only)

1

1

BayStack 450-12F

12 (100BASE-FX only)

1

1

optimal speed, each switched port also
automatically detects and supports 
full-duplex connections to servers, 
power-user endstations or other switches
as well as half-duplex connections to legacy
NICs or hubs. The BayStack 410-24T
Switch is a cost-effective, stackable switch
that supports 24 10BASE-T ports.

High-Density Fiber Ports

The BayStack 450-12F Switch has twelve
100BASE-FX mini MT-RJ ports, one
MDA slot, and a cascade module slot. 
Up to eight BayStack 450-12F Switches
can be stacked to achieve up to 128
100BASE-FX ports (with 4-port
100BASE-FX MDA on each switch). 
The BayStack 450-12F Switch can also 
be stacked with the BayStack 410-24T,
450-12T, and 450-24T Switches to 
accommodate flexible networks.

Redundant Cascade 
Stacking Architecture

Unlike other stacking switches, BayStack
410 and 450 Switches are designed with 
a fail-safe cascade stacking architecture
(see Figure 1). Cascade cables connect 
up to 8 stacked switches into a self-healing
configuration that protects the stack’s
connectivity by looping connection 

As described in Table 1, BayStack 450
Switches are available in 24- and 12-port
configurations, each with a Media
Dependent Adapter (MDA) slot, as well
as a cascade stacking module slot. The
BayStack 410-24T has 24 10BASE-T
ports, one MDA slot, and one cascade
stacking module slot.

Features and Benefits

Flexible High-Speed 
Uplink Options

100BASE-FX and 10BASE-T/100BASE-
TX MDAs for the BayStack 410 and 450
Switches provide high-speed connections
to the network center. Specifically for the
BayStack 450 Switches, Gigabit Ethernet
and future ATM uplinks provide greater
speed connections to the backbone. 

Full Autosensing 
on Every Port

Every UTP port on the BayStack 450-12T
and 450-24T Switches are equipped with
autosense technology to automatically
detect and support the speed and mode of
a connected device. As well as automatically
determining whether a connected device
is operating at 10 Mbps or 100 Mbps 
and automatically adjusting to the 

signals back at a point of failure. In the
unlikely event of a switch failure, all 
other units in a stack remain operational
without interruption.

The redundant cascade stacking 
architecture is a safer, smarter alternative
to current “matrix” stacking switches,
which suffer from a single point of failure
design flaw — should the base unit fail,
all connectivity to all switches in the 
stack is lost.

Wire-speed Throughput

2.5 Gigabit per second (Gbps) switching 
fabric and custom switching ASICs
support full 802.1D-compliant MAC
Layer frame forwarding and filtering
across all ports at the peak rate of 3 million
packets per second for the BayStack 450
Switches. The non-blocking architecture
of the BayStack 410-24T Switch allows
packets to be forwarded at 1 million 
packets per second.

Содержание BayStack 410-24T

Страница 1: ...BASE T switch solution for growing network environments and features fail safe stackability with the BayStack 450 Switches BayStack 410 and 450 Switches also include advanced features such as VLAN tru...

Страница 2: ...s described in Table 1 BayStack 450 Switches are available in 24 and 12 port configurations each with a Media Dependent Adapter MDA slot as well as a cascade stacking module slot The BayStack 410 24T...

Страница 3: ...ting network or endstation performance Enterprise sized MAC Address Table BayStack 410 and 450 Switches support more than 16 000 MAC addresses per switch for deployment of large scale enterprise netwo...

Страница 4: ...tocol SNMP and RMON monitoring and control Network administrators can manage their entire network including all hubs switches and routers from a single management station dramatically reducing the net...

Страница 5: ...802 3u 100BASE TX ISO IEC 8802 3 IEEE 802 1D MAC Bridges ISO IEC 10038 IEEE 802 3z 1000BASE SX and 1000BASE LX Draft Standard ver 3 1 IEEE 802 1p Prioritizing IEEE 802 1Q VLAN Tagging Data Rate and E...

Страница 6: ...ut Power 120 W maximum Input Voltage 100 240 VAC Input Current 1 5 A 100 VAC Thermal Rating 410 Btu hr Physical Dimensions BayStack 450 Switches H 2 77 in x W 17 55 in x D 15 0 in H 7 03 cm x W 44 07...

Страница 7: ...provals UL Listed UL 1950 CSA 22 2 950 with D3 deviations IEC 950 EN 60 950 UL 94 V1 flammability requirements for all PC boards Ordering and Availability Information Table 3 Ordering and Availability...

Страница 8: ...the BayStack 410 and 450 Switches continued Order Number Description Comments AL2033005 BayStack 450 1SX 1 port 1000BASE SX Single PHY MDA For BayStack 450 Switches only AL2033006 BayStack 450 1SR 1...