Nortel BayStack 410-24T Скачать руководство пользователя страница 1

BayStack* 410 and 450 Switches are 
stackable Ethernet switches featuring 
fail-safe stackability, flexible choices 
for high-speed uplinks, and advanced
software features.

BayStack 450 Switches are designed to
provide high-density, high-performance
switching for enterprise wiring closets,
and to provide fail-safe scalability 
and advanced traffic management 
for rapidly growing networks in 
demanding environments. 

The BayStack 410-24T Switch is an
affordable, stackable 10BASE-T switch
solution for growing network environments
and features fail-safe stackability with the
BayStack 450 Switches.

BayStack 410 and 450 Switches also
include advanced features such as VLAN
trunking, priority queuing, and IGMP
snooping. BayStack 450 Switches and
Accelar* Routing Switches also provide
network resilience and advanced 
management with MultiLink Trunking,
LinkSafe* redundant uplink ports,
RMON on every port, complete 
integration into Optivity* network 
management software, and easy-to-use
GUI management.

Stackable Up to 
8 Units and 224 Ports

Fail-Safe Cascade
Stacking
Architecture

Flexible Uplink Options

BayStack

410 and 450 Switches

Product Brief

Содержание BayStack 410-24T

Страница 1: ...BASE T switch solution for growing network environments and features fail safe stackability with the BayStack 450 Switches BayStack 410 and 450 Switches also include advanced features such as VLAN tru...

Страница 2: ...s described in Table 1 BayStack 450 Switches are available in 24 and 12 port configurations each with a Media Dependent Adapter MDA slot as well as a cascade stacking module slot The BayStack 410 24T...

Страница 3: ...ting network or endstation performance Enterprise sized MAC Address Table BayStack 410 and 450 Switches support more than 16 000 MAC addresses per switch for deployment of large scale enterprise netwo...

Страница 4: ...tocol SNMP and RMON monitoring and control Network administrators can manage their entire network including all hubs switches and routers from a single management station dramatically reducing the net...

Страница 5: ...802 3u 100BASE TX ISO IEC 8802 3 IEEE 802 1D MAC Bridges ISO IEC 10038 IEEE 802 3z 1000BASE SX and 1000BASE LX Draft Standard ver 3 1 IEEE 802 1p Prioritizing IEEE 802 1Q VLAN Tagging Data Rate and E...

Страница 6: ...ut Power 120 W maximum Input Voltage 100 240 VAC Input Current 1 5 A 100 VAC Thermal Rating 410 Btu hr Physical Dimensions BayStack 450 Switches H 2 77 in x W 17 55 in x D 15 0 in H 7 03 cm x W 44 07...

Страница 7: ...provals UL Listed UL 1950 CSA 22 2 950 with D3 deviations IEC 950 EN 60 950 UL 94 V1 flammability requirements for all PC boards Ordering and Availability Information Table 3 Ordering and Availability...

Страница 8: ...the BayStack 410 and 450 Switches continued Order Number Description Comments AL2033005 BayStack 450 1SX 1 port 1000BASE SX Single PHY MDA For BayStack 450 Switches only AL2033006 BayStack 450 1SR 1...