background image

302566-A  Rev. 00

    Annex Communications Server R7.1B and Annex Host Tools R14.2 Release Notes

4

DSR Signal

The use of DCD and DSR signals has been split across two parameters: 
need_dsr

 and control_lines. If the parameter need_dsr is set to Y, DSR 

must be asserted to establish a connection on a port. If the parameter 
control_lines

 includes modem_control, that is, the control_lines 

parameter is set to both or modem_control, DCD must be asserted 
to establish a connection. Separating control of these two signals 
provides more flexibility in the use of modem signals.

New Value for output_flow_control

The NA per-port parameter output_flow_control allows the new 
value both. This setting (if control_lines is set to flow_control or to 
both

) enables both in-band (XON/XOFF) and out-of-band (CTS/

RTS) flow control on the Annex III and Micro Annex CD180 serial 
communications chip. These methods of flow control are independent 
and have no overhead since they are handled by the CD180's 
hardware rather than in software.

Setting output_flow_control to both enables both of these flow 
control methods by default. It is then up to the user (via stty), or to 
TELNET or rlogin protocol to disable the XON/XOFF portion of the 
flow control if the remote modem is capable of out-of-band signaling, 
and thus does not need the in-band flow control.

Since the standard character MIB doesn't support both forms of flow 
control at the same time, you can't currently set this option via SNMP, 
and a port with output_flow_control=both will lie to the host and 
say it has hardware flow control enabled when queried via SNMP.

Содержание Annex Host Tools R14.2

Страница 1: ...Resolved with this Release New Features printer_crlf Epson printers monitor pin 14 of the parallel port to decide how to handle CR If pin 14 is high the printer performs a CR If pin 14 is low the prin...

Страница 2: ...an quote a portion of the path that should not be decomposed For example this that theother edu decomposes into this that theother edu and that theother edu When these paths are added the list is chec...

Страница 3: ...n is enabled the Annex always requests for compression and always accepts requests for compression If allow_compression is disabled the Annex never requests for compression and always rejects requests...

Страница 4: ...nes is set to flow_control or to both enables both in band XON XOFF and out of band CTS RTS flow control on the Annex III and Micro Annex CD180 serial communicationschip Thesemethodsofflowcontrolarein...

Страница 5: ...es at 75 second intervals So this time must be added to the tcp_keepalive setting For example if the timer is set to 5 5 seconds the maximum time would be approximately 17 5 minutes Year 2000 Complian...

Страница 6: ...ads its image into flash from any other host and the Annex correctly boots from an Annex boot server R7 1 can not fit into half megabyte of FLASH in self boot units Table 1 Operating System Support Op...

Страница 7: ...equest The work around is to insure that the rs232AsyncPortAutobaud set request is at the end of the set request packet or is alone in the set request Problems Resolved with this Release SPR 11150 The...

Страница 8: ...not supported by the R10 0B release of software The Annex Administrators Guide for Unix that is sent with this release of software mentions several features which are not present in the R10 0B softwa...

Отзывы: