background image

 Install ISDN BRI hardware

Page 15 of 46

ISDN Basic Rate Interface

Installation

Select the card slots 

To install ISDN BRI cards, perform the following steps:

1

Identify all the slots that can contain them. First identify the modules 
with unused network and peripheral card slots and then remove the 
covers from the identified modules. To identify the modules, use the 
following Print Programs. Table 1 lists the modules that can house 
ISDN BRI cards.

LD 22 to print the system configuration and identify unused 
network card slots to install MISPs

LD 20 to list unused IPE card slots to install SILCs, UILCs and 
BRSCs

Table 1
ISDN BRI card location

2

Locate the card slots in the Meridian 1 modules which can house ISDN 
BRI cards. Group all SILCs, UILCs, BRSCs, superloops and the MISP 
that supports them in the same network group to avoid using junctors 
for dedicated connections. 

The following rules apply when selecting the card slots:

Modules

Supported
Systems

SILCs, 
UILCs, 
BRSCs

MISPs

NT5D21 
Core/Network Module

51C, 61C, 
81C 

Network 
slots 
0-7

NT8D35 
Network Module

81C

Network 
slots 
5-12

NT8D37 
IPE Module

All systems

IPE slots 
0-15

Содержание 553-3901-200

Страница 1: ...igital device pursuant to Part 15 of the FCC rules and the radio interference regulations of Industry Canada These limits are designed to provide reasonable protection against harmful interference whe...

Страница 2: ......

Страница 3: ...types except Options 11C 51C 61C and 81C and references to previous software releases October 1997 Issue 5 00 released as Standard for Generic X11 Release 23 00 August 1996 Issue 4 00 released as Stan...

Страница 4: ...Page 4 of 46 553 3901 200 Standard 7 00 January 2002...

Страница 5: ...Page 5 of 46 ISDN Basic Rate Interface Installation 6 Contents About this document 7 Preinstallation preparation 9 Install ISDN BRI hardware 13...

Страница 6: ...Page 6 of 46 Contents 553 3901 200 Standard 7 00 January 2002...

Страница 7: ...is document is a global document Contact your system supplier or your Nortel Networks representative to verify that the hardware and software described is supported in your area Note 1 For Option 11C...

Страница 8: ...Page 8 of 46 About this document 553 3901 200 Standard 7 00 January 2002...

Страница 9: ...the references in this section Installation Planning 553 3001 120 System Engineering 553 3001 151 Power Engineering 553 3001 152 System Installation Procedures 553 3001 210 ISDN Basic Rate Interface P...

Страница 10: ...g guidelines of ISDN Basic Rate Interface Product Description 553 3901 100 Refer to System Installation Procedures 553 3001 210 for a description of how to install the modules Unpack and inspect ISDN...

Страница 11: ...hem Do not stack the plug in cards on top of each other This can damage the components and the printed circuits on the cards Take inventory After unpacking verify that all the equipment necessary is a...

Страница 12: ...Page 12 of 46 Preinstallation preparation 553 3901 200 Standard 7 00 January 2002...

Страница 13: ...DN BRI terminals to Meridian 1 22 Install ISDN BRI hardware for trunk applications 38 Select the card slots 38 Remove the module cover for card installation 38 Install the MISP 38 Install the clock re...

Страница 14: ...be installed and operating according to the instructions in System Installation Procedures 553 3001 210 before performing these procedures For a successful installation perform these procedures in th...

Страница 15: ...e system configuration and identify unused network card slots to install MISPs LD 20 to list unused IPE card slots to install SILCs UILCs and BRSCs Table 1 ISDN BRI card location 2 Locate the card slo...

Страница 16: ...An MISP supports a set of four SILCs or UILCs when not supporting a BRSC An MISP can support both BRSCs and SILCs or UILCs at the same time If it serves one BRSC a MISP can also support three line car...

Страница 17: ...sing junctors for dedicated connections The figures that follow show typical module configurations Figure 1 shows the NT8D35 Network module Figure 2 shows the NT8D37 IPE module Figure 3 shows the NT5D...

Страница 18: ...al Equipment Superloop Shelf IPE PE Module PE Pwr Sup Rng Gen 0 2 3 4 5 6 7 Cont 9 11 12 13 15 1 8 14 10 Intelligent Peripheral Equipment Superloop Shelf IPE PE Module PE Pwr Sup Rng Gen Intelligent l...

Страница 19: ...o it does not fall off slide the latches toward the center of the cover 4 Pull the cover toward you and lift it away from the module 5 Place the cover in a safe place away from the working area to avo...

Страница 20: ...the card 2 Insert the MISP into the selected card slot of the module so it engages the card guides in the module 3 Slide the MISP into the module until it engages the backplane connector 4 Push the MI...

Страница 21: ...bs out and away from the card 2 Carefully remove the MISP from its card slot and slowly slide out the card from the module End of Procedure Install the BRSC SILC and UILC After MISPs are installed ins...

Страница 22: ...or IPE Module Card Location Form fill in the card type and the module number next to the slot number of the installed card 8 Repeat steps 1 through 7 for each card requiring installation End of Proce...

Страница 23: ...BRI terminals to Meridian 1 Meridian1 IPEI OPanel NE A25BCable Intermediate Distribution Frames 553 5459 Terminating Resistor Main Distribution Frame SILC DSL Office Wiring Wall Outlets Modular Cable...

Страница 24: ...ing the module number the connector name A B C and the card type SILC or UILC 3 Plug one end of a cable into the appropriate connector on the I O panel at the rear of the Meridian 1 module Plug the ot...

Страница 25: ...to the MDF SILC UILC port designations at the MDF The tables that follow provide SILC UILC port designations at the MDF for the NT8D37 IPE Meridian1 NE A25B External Communication Cable A B J2 A F E...

Страница 26: ...R R 0 T T R R 1 T T R R 2 T T R R 3 T T R R 4 T T R R 5 T T R R 6 T T R R 7 E F T T R R 0 T T R R 1 T T R R 2 T T R R 3 T T R R 4 T T R R 5 T T R R 6 T T R R 7 F G T T R R 0 T T R R 1 T T R R 2 T T R...

Страница 27: ...al simplexed over the transmit and receive pairs where the transmit pair is negative with respect to the receive pair Table 3 UILC port designation labels at the MDF NT8D37 IPE Module 16 cable configu...

Страница 28: ...ese DSLs are not polarity sensitive and although it is recommended it is not necessary to maintain signal polarity along each loop Figure 7 and Figure 8 illustrate respectively a cross connection of a...

Страница 29: ...to Tables 4 through 10 which follow the illustrations Note In Tables 4 through 10 the cable pair designated T T is the transmit pair and the pair designated R R is the receive pair of the S T interfac...

Страница 30: ...5B cable connector connecting distribution frame connector A Note 1 Substitute Tx Tx Rx Rx for every occurance of T T R R Note 2 Transmit and receive labeling is from the network perspective T T R R T...

Страница 31: ...ort 2 Port 3 Port 4 Port 5 Port 6 Port 7 1 2 3 4 5 6 7 8 R T T R P P WHT ORG BLU WHT WHT BLU ORG WHT GRN WHT WHT GRN NE A25B cable connector connecting distribution frame connector A T R T R T R T R T...

Страница 32: ...0Tx 0Tx 0Rx 0Rx 0T 0R 26 1 27 2 W BL BL W W O O W slot 0 slot 4 slot 8 slot 12 0 1Tx 1Tx 1Rx 1Rx 1T 1R 28 3 29 4 W G G W W BR BR W 1 2Tx 2Tx 2Rx 2Rx 2T 2R 30 5 31 6 W S S W R BL BL R 2 3Tx 3Tx 3Rx 3R...

Страница 33: ...W BR BR W 1 2Tx 2Tx 2Rx 2Rx 2T 2R 30 5 31 6 W S S W R BL BL R 2 3Tx 3Tx 3Rx 3Rx 3T 3R 32 7 33 8 R O O R R G G R 3 4Tx 4Tx 4Rx 4Rx 4T 4R 34 9 35 10 R BR BR R R S S R 4 5Tx 5Tx 5Rx 5Rx 5T 5R 36 11 37 12...

Страница 34: ...W BR BR W 5 6Tx 6Tx 6Rx 6Rx 6T 6R 30 5 31 6 W S S W R BL BL R 6 7Tx 7Tx 7Rx 7Rx 7T 7R 32 7 33 8 R O O R R G G R 7 0Tx 0Tx 0Rx 0Rx 0T 0R 34 9 35 10 R BR BR R R S S R slot 3 slot 7 slot 11 slot 15 0 1T...

Страница 35: ...plug the power source into the wall outlet then plug the cable into the power source s RJ 45 jack This power source must supply power only to the local ISDN BRI terminal not back into the DSL through...

Страница 36: ...3 4 5 6 7 8 3 4 5 6 7 8 OptionalPowerAdapter RJ 45type walloutlet RJ 45typeplug S Tinterface Optional externalpower source PS52 3Rx 4Tx 5Tx 6Rx 7P 8P VoiceData terminal 1 2 3Tx 4 Rx 5Rx 6Tx 7P 8P S T...

Страница 37: ...4 WHT BLU Tx 5 ORG WHT Rx 6 GRN WHT P 7 WHT GRN P 8 S T Interface Connector on the Network Termination NT1 U Interface Connector on the Network Termination NT1 1 2 3 4 R 5T 6 7 8 1 2 P 7 P 8 R 3 T 4...

Страница 38: ...quipment mode Note The Meridian 1 in Tie trunk or CO connectivity requires a different wiring configuration than for a line application the transmit and receive pairs should be reversed as illustrated...

Страница 39: ...ewire the selected Tx and Rx pairs applicable to DSL0 and DSL1 to exchange the Tx and Rx pair position This rewiring is done at the Main Distribution Frame MDF 2 Remove the phantom power jumpers two j...

Страница 40: ...sub 9 connector slots on the I O panels of the selected IPE and CE I O modules if the I O panel is equipped with D sub 9 connector slots If none is available look for an empty slot used for 25 pair w...

Страница 41: ...et up through the Maintenance Signaling Channel MSC The microcontroller configures the S T chips on the SILC as appropriate The SILC may recover the network clock from the received data stream using o...

Страница 42: ...nce clock if defined Install the SILC and the UILC Follow the same procedures as described earlier for line applications refer to Install the BRSC SILC and UILC on page 21 Connect Meridian 1 to the Ma...

Страница 43: ...5 6 7 8 9 10 11 12 DSL 2 Distribution Frame Tx Rx Tx Rx Tx Rx Tx Rx DSL 1 Wiring for SILC Port 0 WHT ORG Network Termination NT1 S T Interface Connector on the Network Termination NT1 U Interface Con...

Страница 44: ...ling SILC UILC and BRSC cards on the Meridian 1 Table 9 Card location form NT8D37 IPE Module 16 cable configuration Card type SILC UILC BRSC IPE Module number IPE Module slot number I O panel connecto...

Страница 45: ...m NT8D37 IPE Module 12 cable configuration Card Type SILC UILC or BRSC IPE Module number IPE module slot number I O panel connector SILC UILC or BRSC ports 0 A 0 7 1 B 0 7 2 B C 0 3 4 7 3 C 0 7 4 E 0...

Страница 46: ...Page 46 of 46 Install ISDN BRI hardware 553 3901 200 Standard 7 00 January 2002...

Страница 47: ......

Страница 48: ...ules and the radio interference regulations of Industry Canada These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial en...

Отзывы: