Configuring PoE using the CLI
161
"poe-power-usage-threshold parameters" (page 161)
outlines the
parameters for this command.
poe-power-usage-threshold parameters
Parameter
Description
unit <1 - 8>
The unit for which to set the power threshold.
<1 - 99>
1—99 percent
Run the
show poe-main-configure
command in Global Configuration
command mode.
Setting PoE detection method
The
poe-pd-detect-type
command enables either 802.3af or Legacy
compliant PD detection methods.
The syntax for the
poe-pd-detect-type 802dot3af_and_legacy
command is
poe poe-pd-detect-type [unit <1-8>] {802dot3af |
802dot3af_and_legacy}
Run the
poe-pd-detect-type 802dot3af_and_legacy
command in
Global Configuration command mode.
Show port power status
The
show port power status
command displays the power
configuration.
The syntax for the
show port power status
command is
show poe-port-status [<portlist>]
Substitute
<portlist>
with the ports for which to display configuration.
Run the
show poe-port-status
command in Global Configuration
command mode.
Show port power measurement
The
show port power measurement
command displays the power
configuration.
The syntax for the
show port power measurement
command is
show poe-power-measurement [<portlist>]
Substitute
<portlist>
with the ports for which to display configuration.
Nortel Ethernet Routing Switch 4500 Series
Overview — System Configuration
NN47205-500
02.01
Standard
5.0
23 February 2007
Copyright © 2007, Nortel Networks
Nortel Networks Confidential
.