74
Chapter 4 Installing option cards and DIMMs
NN46110-318 02.01
5
To replace a DIMM, remove the installed DIMM as follows:
a
Press down the locking lever on either side of the DIMM
(Figure 26)
.
b
Pull the DIMM up to remove it from the slot.
6
Press down the locking lever on either side of the slot where you plan to
install the new DIMM
(Figure 26)
.
7
Place the new or replacement DIMM in the slot
(Figure 26)
.
Use the alignment keys to properly position the DIMM in the slot.
8
Press the DIMM firmly into the socket.
9
Pull up the locking lever on either side of the DIMM to snap it into position.
Figure 26
Installing and removing a DIMM
To remove DIMMs, pull back
locking levers and pull out DIMM.
To install DIMMs, pull back locking
levers and push in DIMM.
Locking lever
Alignment keys
CS260019A