Configure E1/T1 ports on a Call Server
93
DPNSS/DASS configuration - DDSL data blocks
Procedure 22 “Configuring DPNSS/DASS D-channel interface using LD
74” (page 93)
describes the configuration required for the DDSL data
blocks used for DPNSS protocols.
Procedure 22
Configuring DPNSS/DASS D-channel interface using LD 74
Step
Action
1
Log on to the CS 1000E.
2
To access LD 74, enter:
LD 74
3
Enter the responses shown in
D-channel interface configuration (LD 74)" (page 93)
Table 23
DPNSS/DASS D-channel interface configuration (LD 74)
Prompt
Response
Description
REQ
NEW
New data.
TYPE
DDSL
Digital Signaling Link.
S2
0
DCHI switch setting (the normal addressing mode for
MGP).
DDSL
0 - 15
The D-channel logical port number, entered in LD 17.
SIGL
DA
DPNSS1/DASS2 digital signaling.
DDCS
0 - 254
Loop number used for the PRI link (reference to DDCS in
LD 17).
PRIV
YES/NO
YES = Private DPNSS1 link.
NO = DASS2 link.
SIDE
AET/BNT
The AET/BNT end of DPNSS1 link.
...
...
--End--
Configure CE-MUX clock controllers
You must configure the CE-MUX clock controllers as well as error
detection thresholds in PRI Gateway.
These prompts are enabled when the IPMG package (package number
403) is enabled, regardless of the state of the softswitch package.