Configure the Media Gateway Controller and DSP daughterboards in a PRI Gateway
For more information about configuring DTMF tone detection (DTR),
see Communication Server 1000E Installation and Commissioning
(NN43041-310).
Procedure 12
Configuring the Media Gateway Controller on a Call Server using LD 97
Step
Action
1
Log on to the CS 1000E Call Server.
2
To access LD 97, enter:
LD 97
3
Enter the responses shown in
Controller configuration (LD 97)" (page 70)
.
Table 13
Media Gateway Controller configuration (LD 97)
Prompt
Response
Description
REQ
aaa
Request (aaa = CHG, NEW)
TYPE
Supl
Superloop
SUPL
0–252
Superloop number. Add prefix X to delete.
SLOT
<CR>
Select default.
SUPT
IPMG
IP Media Gateway
The following prompts are for IPMG superloops only.
IPR0
nn.nn.nn.nn
Shelf 0 IPMG Uplink IP address. <CR> to skip to IPR1
when configuring new superloop; X to remove IPR0, DES0,
and ZONE0 data.
IPMG_TYPE
MGC
IPMG is controlled by MGC card.
ZONE0
0-8000
Shelf 0 IPMG zone number. Zones used for IPMG
purposes must be configured as shared so that other IP
devices that are not in the same zone can gain access to
the IPMG devices.
DES0
No input, simply a header for the ELAN/TLAN designators.
This header and the ELAN/TLAN prompts only apply to
MGC-based IPMGs.
...
...
DES1
No input, simply a header for the ELAN/TLAN designators.
This header and the ELAN/TLAN prompts only apply to
MGC-based IPMGs.
...
...
--End--
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.