155
.
Appendix
Media Gateway Controller system
alarms, events, and messages
The Media Gateway Controller (MGC) platform displays the messages
shown in
Table 40 "MGC system alarms, events, and messages" (page
. They include, for example, hardware level faults and firmware faults,
including Tones and Conference, Call Server synchronization problems.
Table 40
MGC system alarms, events, and messages
Message
Severity
Description
Corrective action
Output
(TTY, LOG,
SNMP, LED)
MGC0000
Critical
Cold start of the MGC
<supl shelf> occurred.
Reason: <Power cycle
/ Hardware watchdog
expired / User initiated/
Software error>.
Depending on the
reason code, contact
Nortel support.
TTY, LOG,
SNMP
MGC0001
Critical
Warm start of the MGC
<supl shelf> occurred.
Reason: <Normal after
cold start / Rest button
pressed / User initiated /
Software error>.
Depending on the
reason code, contact
Nortel support.
TTY, LOG,
SNMP
MGC0002
(E002)
Critical
Unable to send MGC <supl
shelf> registration request
to the Call Server.
Check IP configuration
and network
connections.
TTY, LOG,
SNMP, LED
MGC0003
Clear
(E002)
MGC <supl shelf>
registered to the Call
Server.
None
TTY, LOG,
SNMP, LED