Configure E1/T1 ports on a Call Server
103
7
From the menu, select disable MSDL Device (DIS) and select
the All check box.
8
Select the radio button for the MSDL (MG_Card).
9
Click Submit.
10
Click OK
11
Return to the D-Channel configuration page and make the
required changes.
12
Return to the MSDL diagnostics page.
13
From the menu, select the enable MSDL Device (ENL)
command and select the All check box.
14
Select the radio button for the MSDL (MG_Card).
15
Click Submit.
16
Click OK
--End--
Procedure 32 “Configuring the DPNSS/DASS trunks with Trunk Data Block
data using LD 14” (page 103)
describes how to configure the DPNSS
trunks with Trunk Data Block data. This configuration is required for both
real (RDC) and virtual (VDC) channel types.
ATTENTION
VDC configuration is not required for DASS signaling.
Procedure 32
Configuring the DPNSS/DASS trunks with Trunk Data Block data using LD 14
Step
Action
1
Log on to the CS 1000E.
2
To access LD 14, enter:
LD 14
3
Enter the responses shown in
Table 31 "Trunk Data Block data
for DPNSS/DASS trunks (LD 14)" (page 103)
Table 31
Trunk Data Block data for DPNSS/DASS trunks (LD 14)
Prompt
Response
Description
REQ
aaa
Request (aaa = CHG, NEW)
TYPE
RDC/VDC
Real/virtual digital channel.
TN
l ch
Terminal Number for digital trunks where l = loop,
ch = channel.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.
Содержание 1000E PRI