background image

3

Figure 1. Typical Digital Thermostat

Fan

Mode

Temperature

Selector

System

Mode

Operating the Heat Pump for Automatic 
Cooling & Heating (Autochangeover)

1. Set the thermostat system switch to AUTO and the 

thermostat fan switch to AUTO.

NOTE:

 Thermostats will vary. Some models will not 

include the AUTO mode, others will have the AUTO in 
place of HEAT and COOL, and some will include all three.

2. Set the thermostat temperature to the desired heating 

and cooling temperature level(s). The outdoor unit and 
the indoor blower will then cycle on and off in either 
the heating or cooling mode of operation as required 
to automatically maintain the indoor temperature within 
the desired limits.

Operating the Indoor Blower Continuously

Continuous indoor blower operation is typically used to 
circulate the indoor air to equalize a temperature imbalance 
due to a solar load, cooking, or fireplace operation.

Set the thermostat fan mode to ON (Figure 1). The indoor 
blower starts immediately, and will run continuously until 
the fan mode is reset to AUTO. 

Continuous indoor blower operation can be obtained 
with the thermostat system mode set in any position, 
including OFF.

Shutting the Heat Pump Off

Change the thermostat’s system mode to OFF and the 
fan mode to AUTO. 

NOTE:

 The system will not operate, 

regardless of the temperature selector setting.

TROUBLESHOOTING

Before you call a Technician, check the following:
•  Check the thermostat setting. Make sure the system 

mode and temperature settings are correct.

•  Check the electrical panel for tripped circuit breakers. 
•  Check the filters for dust accumulation.
•  Check the unit and make sure it is clean and not covered 

with grass or leaves.

•  If the items above don’t resolve your problems, then 

call your nearest service technician.

HEAT PUMP MAINTENANCE

 WARNING:

This heat pump contains liquid and gaseous 
refrigerant under pressure. Installation and 
servicing should only be attempted by qualified, 
trained personnel thoroughly familiar with the 
equipment and safe responsible refrigerant 
handling procedures. Failure to comply with 
this warning could result in equipment damage, 
personal injury, or death.

 WARNING:

To prevent electrical shock, personal injury, 
or death, disconnect all electrical power to 
the unit before performing any maintenance 
or service. The unit may have more than one 
electrical supply.

Proper maintenance is important to achieve optimum 
performance from the heat pump. The ability to properly 
perform maintenance on this equipment requires certain 
mechanical skills and tools. If you do not possess these 
skills, contact your dealer for maintenance. Consult your 
local dealer about the availability of maintenance contracts. 
Routine maintenance should include the following:

Regular Cleaning

 CAUTION:

DO NOT touch any of the internal electrical 
components while cleaning the unit.

•  The area around the unit and the vicinity of any other  

appliances must be kept clear and free of combustible 
materials, gasoline, and other flammable vapors and 
liquids. Do not store or use flammable items such as 
gasoline, paint, varnish, or strippers in the vicinity of 
the unit.

•  Keep the outdoor unit clean. Hose off periodically and 

keep unit fins clear of leaves and grass clippings. 

Be 

careful not to damage the aluminum fins

. Clean 

Содержание PSH4BG

Страница 1: ...thoroughly before using the equipment Follow all precautions and warnings contained within these instructions and on the unit Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance DO NOT DESTROY PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE WARNING To achieve optimum performance and minimize equipment failure it is r...

Страница 2: ...pump model Heating Operation Only 1 Set the thermostat s system mode to HEAT and change the fan mode to AUTO 2 Setthetemperatureselectortothedesiredtemperature level The compressor outdoor fan and blower motor will cycle on and off to maintain the indoor temperature at the desired heating level NOTE If the temperature level is re adjusted or the system mode is reset the fan and compressor in the o...

Страница 3: ...or tripped circuit breakers Check the filters for dust accumulation Checktheunitandmakesureitiscleanandnotcovered with grass or leaves If the items above don t resolve your problems then call your nearest service technician HEAT PUMP MAINTENANCE WARNING This heat pump contains liquid and gaseous refrigerant under pressure Installation and servicingshouldonlybeattemptedbyqualified trained personnel...

Страница 4: ...the unit to ensure that it is physically sound without sagging cracks gaps etc Air Filters WARNING Never operate the unit without a filter in the return air system Dust and lint in the return air can build up on the internal components resulting in loss of efficiency equipment damage and possible fire risk Inspect and clean or replace air filters at the beginning ofeachheatingandcoolingseason ormo...