INSTALLATION CHECKLIST

10402400

(NEW)

REPLACEMENT PARTS

Replacement parts are available through your distributor. Please 

have the complete model and serial number of the unit when 

ordering replacement parts.

ELECTRICAL:

• Capacitors

•  Temperature Limit Switches

• Compressors

• Thermostats

• Contactors

•  Time Delay Relays

•  Pressure Switches

• Transformers

MOTORS:

•  Blower Motor
•  Fan Motor

COMPONENTS:

•  Blower Assembly

•  Fan Grille

•  Cabinet Panels

• Filter/Driers

•  Expansion Valves

REFRIGERATION SYSTEM

Was unit given 24 hr warm up period 

for crankcase heaters (if equipped)?

YES

NO

Stage-1 Liquid Pressure (high side) _______________________________________________________

Stage-1 Suction Pressure (low side) _______________________________________________________

ELECTRICAL SYSTEM

Electrical connections tight?

YES

NO

Line voltage polarity correct?

YES

NO

Has the thermostat been calibrated?

YES

NO

Is the thermostat level?

YES

NO

Is the heat anticipator setting correct?

(If Applicable)

YES

NO

Rated Voltage: _________________________________________________________________ VOLTS

L1-L2 Volts: ___________________________________________________________________ VOLTS

INSTALLATION ADDRESS:

CITY _________________________________________

STATE _____________________________

UNIT MODEL # _______________________________________________________________________

UNIT SERIAL # _______________________________________________________________________

Unit Installed Minimum clearances per 

Figure 1 (page 4)

?

YES

NO

INSTALLER NAME:

CITY _________________________________________

STATE _____________________________

Has the owner’s information been 

reviewed with the customer?

YES

NO

Has the Literature Package been left 

with the unit?

YES

NO

Specifications & illustrations subject to change without notice or incurring obligations (03/22).
© Nortek Global HVAC LLC 2022. All Rights Reserved.

Содержание P94RD Series

Страница 1: ...plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings co...

Страница 2: ...te a degree or level of seriousness and should not be ignored WARNING indicates a potentially hazardous situation that if not avoided could result in personal injury or death CAUTION indicates a poten...

Страница 3: ...om the airflow data found in Table 3 page 11 Place appropriate wire on the appropriate motor speed tap for the required airflow GENERAL INFORMATION This packaged air conditioner is designed only for o...

Страница 4: ...visit www NFPA org on the web Design the duct work according to methods described by the Air Conditioning Contractors of America ACCA The supply duct system including the number and type of registers...

Страница 5: ...an open area equal to or greater than a 12 x 20 grille The return air grille can be placed in the wall of a closet and the air ducted into the filter box through a boxed in area at the closet floor le...

Страница 6: ...w safety warnings exactly could resultinseriousinjury deathorpropertydamage Improper servicing could result in dangerous operation serious injury death or property damage Beforeservicing disconnectall...

Страница 7: ...of the NEC ANSI NFPA 70 and with applicable localcodeshavingjurisdiction Thermostatconnectionsshould Low Voltage Line Voltage be made in accordance with the instructions supplied with the thermostat...

Страница 8: ...t 24 hours prior to running After unit startup the compressor must run for a minimum of 12 hours Start Up Procedure CAUTION If the unit is equipped with a crankcase heater allow 24 hours prior to cont...

Страница 9: ...rical shock personal injury or death disconnect all electrical power to the unit before performing any maintenance or service The unit may have more than one electrical supply Proper maintenance is im...

Страница 10: ...3 Ton 2 B 5 5 3 Opening for 12 Diameter Supply Duct Opening for 12 Diameter Return Duct A 17 50 8 9 1 B 8 A 5 5 3 17 50 9 2 9 1 Opening for 14 Diameter Return Duct Opening for 12 Diameter Supply Duct...

Страница 11: ...252 25 1210 26 1161 27 1120 28 1071 30 1013 31 954 33 Tap T3 1460 22 1 415 22 1385 23 1335 24 1275 25 1 225 26 1 170 27 1120 28 Tap T4 1618 20 1 580 20 1543 20 1508 21 1478 21 1 443 22 1 388 23 1 345...

Страница 12: ...EQUALIZATION VALVE 24V C R E Y2 Y1 W2 O G 1 Couper le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre F...

Страница 13: ...C T STAT TERMINAL 24V GREEN 1 Couper le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LE...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...O Has the thermostat been calibrated YES NO Is the thermostat level YES NO Is the heat anticipator setting correct If Applicable YES NO Rated Voltage __________________________________________________...

Отзывы: