background image

16

 Annunciate  Trouble  Indication

With this option box checked, the Console will announce three system 
trouble conditions if they occur: Console low battery, sensor low battery, 
and no sensor status. Sensor troubles type are announced followed by the 
sensor zone number. The default is to 

not 

annunciate these conditions.

 

NOTE FOR UL APPLICATION

S

: UL requires the Annunciation Trouble 

Indication option to be enabled (option box checked).

 Annunciate Status with Home Button

A short press of the  

HOME

 button will cause the Console to announce 

the Console’s time, current mode, and any trouble conditions. The default 
for status annunciations is enabled. Optionally, status annunciations can 
be disabled by un-checking this option box.

 Annunciate Phone-Line/AC/Cell Module Status

If the telephone line is disconnected, or the AC power to the Console 
fails, or the cellular module is off-line, the Console can annunciate these 
conditions. These annunciations will clear when the condition is corrected.

The default sets these types of annunciations to 

ANNUNCIATE ONCE

Alternately, use the this option to select 

OFF

 or 

ANNUNCIATE EVERY 

HOUR

. Regardless of this setting, the Console records the condition in 

the event log and can report AC power failure to the Central Station (if 
AC reporting is enabled).

 

NOTE: To prevent disturbing the User, these annunciations will be 
suppressed while the Console is in Night Mode.

 Clock  Annunciation  Format

Both 12-hour (AM/PM) and 24-hour (“military”) time formats are 
supported in time announcements for Console status. 

The default sets the time annunciations to  

12-HOUR CLOCK

 format. 

Alternately, use the this option to select  

24-HOUR CLOCK

 format.

 Data  version

Displays the version number of the Console’s data for factory use and 
troubleshooting.

 Console Confi guration Misc.

Displays confi guration numbers of the Console for factory use and 
troubleshooting.

 CPU  Identifi er

For factory use.

 Language  Selection

If the selection is NOT grayed out, the Console can annunciate voice 
prompts in English or Spanish to guide the user during operation, and 
guide the Dealer or Installer during programming.

The two resident languages in the Console are English (EN) and 
Spanish (ES). 

Choose the active language for the Console using the 

radio buttons in the Language Selection area.

To use a different language, the language vocabulary fi le  must 
fi rst be downloaded and installed in the Console’s fi rmware (See 
Section 16.2).

 Temperature Limit Settings

Temperature

 

measurement is not available on the PERS-4200X and the 

selection is grayed out.

 Console  Time  Settings

The Console contains a built-in clock and calendar, and supports 
automatic daylight saving time adjustment. The Console’s current time 
and date setting and the daylight saving information is displayed on the 
Console tab or the RA4200 software.

To change these settings, the Dealer or Installer should use the 

CONSOLE TIME

 function on the 

COMMUNICATION

 menu (or press the 

CONSOLE TIME

 icon on the toolbar ribbon). See Section 12.3.

 

NOTE: If the UMT

S

-3G/V2 cellular module is installed, the Console’s 

time will be set automatically over the air by the network.

 Activity  Windows

The  activity timer is a feature that requires the User to press the Console’s 
 

HOME

 button or activate a activity reset transmitter during one or two 

preset time windows to 

prevent

 an inactivity alarm from being reported.

Two activity time windows can be set by the Dealer or Installer. Each time 
window can be enabled or disabled, and has a start and stop time.

• To enable 

Activity Window 1

 and/or 

Activity Window 2

, check the enable 

box next to the start and stop times.

•  Set the start time for the activity window.
•  Set the stop time for the activity window.

 Night  Mode

Night Mode is an option that will suspend all Console supervisory 
annunciations during the Night Mode time window. This mode allows the 
user to sleep without interruptions from the Console about non-emergency 
conditions.

•  To enable the 

Night Mode

 time window, check the enable box next to the 

start and stop times.

•  Set the start time for Night Mode.
•  Set the stop time for Night Mode.

Содержание Numera PERS-4200X Series

Страница 1: ...INSTR INSTL PERS 4200X P N 10007317 B INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 TOLERANCE 125 SCALE 1 1 FOLDING ALBUM FOLD BINDING SADDLE STITCH www nortekcontrol com MHz 2GIG 345 PERS 4...

Страница 2: ...cs equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment W E E E The separate collection and recycling of your waste electrical a...

Страница 3: ...User Password 15 Provider Password 15 Mode After Disconnect 15 Transmission Supervision Interval 15 Emergency Siren 15 Voice Prompts 15 Annunciate Trouble Indication 16 Annunciate Status with Home Bu...

Страница 4: ...detectors Wireless transmitters can also be configured as activity timer reset devices to verify activity at the User s location 1 1 Console Features Voice Prompts A built in digital voice synthesize...

Страница 5: ...itters can be wired to a pushbutton or switch for manual activity monitoring As long as a signal is received from each activity sensor during a programmed activity time window an alarm will not be tri...

Страница 6: ...lations where the activity timer will not be used a snap on button cover is supplied to hide the HOME button NOTE The HOME button cover cannot be easily removed once the cover is in place PERS 4200X C...

Страница 7: ...LOCAL PROGRAMMING ONLY INSERT USB PLUG INTO PROGRAMMING COMPUTER USB PORT OPTION MODULES PLUG INTO CONSOLE CELLULAR TELEPHONE MODULE REMOTE SPEAKER MICROPHONE MODULE BE SURE TO SECURE MODULES WITH SCR...

Страница 8: ...me controls are provided to customize the sound levels of the Console for the installation The Dealer or Installer should use their judgment and expertise in determining the appropriate volume level f...

Страница 9: ...y The Console will start the Two way audio session if enabled IfTwo way audio is not enabled after the report is completed the Console will announce 0 Emergency reported 4 4 User Features Several feat...

Страница 10: ...Programming Mode the Console is not operational and cannot receive or report alarms 5 4 Test Learn Mode Test Learn Mode is accessible using the TEST button on the Console This mode can be used to loca...

Страница 11: ...ch account template file 6 2 RA4200 FAQ How does RA4200 connect to a Console RA4200 can connect to the Console two ways Remote connection over the telephone line using the computer s modem Local USB c...

Страница 12: ...0 Software Installation The RA4200 remote access software is available on the Web at this link www nortekcontrol com downloads php The installation program will create a directory on your hard disk dr...

Страница 13: ...the Modem in Windows Windows Control Panel can be used to test the modem and determine what COM port the modem is connected to 1 Open Windows Control Panel 2 Select PHONE AND MODEM 3 Click on the MOD...

Страница 14: ...et Several other Console options and settings are also available in this tab The Console s time and date settings are displayed Sensors Displays the 16 wireless sensor zones of the PERS 4200X Console...

Страница 15: ...export file to be sent to the Console using the Management Server This feature requires an internet connection This is an alternate way to change the Console configuration Think of the Management Ser...

Страница 16: ...ammed information from an already programmed Console although the data on the Customer tab will be lost and have to be reentered 11 2 Customer Tab The Customer tab displays fill in fields for details...

Страница 17: ...detectors These types of sensors are always set by the Console to require reception of a status signal at least once every 24 hours Select one of the six options for the supervision interval 12 hours...

Страница 18: ...tion is NOT grayed out the Console can annunciate voice prompts in English or Spanish to guide the user during operation and guide the Dealer or Installer during programming The two resident languages...

Страница 19: ...om a wireless sensor two options are available to control when the Console reports a low sensor battery Option 1 When a low battery signal is received from a sensor the Console will immediately report...

Страница 20: ...ters in field units easier Select AUTO DETECT for a sensor zone to automatically detect if a wireless transmitter is sending status signals Once the Console detects status signals from a transmitter i...

Страница 21: ...k option is selected the Two way audio setting will automatically adjust for the reporting method chosen PSTN or IP reporting PSTN Dialing Sequence The Console will make multiple attempts to make a co...

Страница 22: ...have the Console speaker active during dialing PrimaryTelephone Number The primary telephone number is the number that will be dialed first in the dialing sequence The number can be up to 20 digits i...

Страница 23: ...formed for cellular reporting Note that an appropriate mobile terminated voice service plan is needed to use this feature The Two Way Audio Mode must also be enabled for callback to work Event Account...

Страница 24: ...ice plan for the device Dealers will also have to change the configuration of the Console to use the gprs02 motient net APN IP service field to support call back See the example of the typicalTelit m2...

Страница 25: ...ode and announce FW Version and HW Version Press the HELP button while in Test Mode Console checks the presence of hardware if a Cellular Module is installed the Console announces Cellular module dete...

Страница 26: ...only works with 2GIG fall detection sensors when used with the PERS 4200X Console that supports fall detection reporting The default setting enables fall detection reporting Un check to disable fall d...

Страница 27: ...nnot be cancelled The default setting for dialing delay is OFF Two way Audio Mode The Console supports Two way audio communications with the User through the Console s speaker and microphone The defau...

Страница 28: ...ENABLE box 2 Click the TEST REMINDER button 3 Select a Day of Month and Time for the monthly test message to occur 4 Click OK Test Reminder Operation When the programmed system test time occurs a rem...

Страница 29: ...layed in the RA4200 connection status area 5 The modem will place a call to the Console wait a few rings then hang up This readies the Console to answer a call The modem will call the Console again th...

Страница 30: ...date If daylight saving time is enabled verify the start and stop dates Press SET TIME to update the Console s date and time Press DONE 4 Press SET CONSOLE The template will be sent to the Console 5 P...

Страница 31: ...0 Press nine to hang up 0 Press zero for main menu If selecting a new format the Console will announce over the telephone 0 Report format is reporting format press pound to accept or press star to ch...

Страница 32: ...ber 2 Press and release the TEST button again The Console will announce 0 Ready to learn sensor Zone number 3 Activate the sensor to learn The Console will announce 0 Fire Activity Emergency Carbon Mo...

Страница 33: ...unce 0 Fire Activity Emergency Carbon Monoxide sensor zone number full or low signal If the sensor tested has a low battery the Console will announce 0 Sensor low battery zone number 3 When finished p...

Страница 34: ...remote access events are logged Remote access RA4200 sessions Console supervisory events AC power low battery phone trouble Sensor supervisory events supervision low battery NOTE Extended event loggin...

Страница 35: ...he FILE menu select PRINT PREVIEW or on the toolbar click the PRINT icon 3 The Account Information print preview window will be displayed The preview shows the account template contents detailed on se...

Страница 36: ...1 Click LEAVE DFU MODE The RA4200 will disconnect the Console and the Console will reset 12 Click QUIT to exit the DfuSe utility 13 Configure the Console with the RA4200 as required NOTE Should any pr...

Страница 37: ...35 DfuSe Utility Connected to Console Firmware File Selection Verify and Target ID Selection Upgrading in Process DfuSe Device Warning Upgrade Complete...

Страница 38: ...E LOW BATTERY 1 1384 XX 2 40 SENSOR FT FIRE SMOKE SUPERVISORY 1200 XX 2 40 SENSOR FS FIRE SMOKE SUPERVISORY RESTORE 3200 XX 2 40 SENSOR FQ CO ALARM GAS 1162 XX 2 10 SENSOR GA CO LOW BATTERY 1384 XX 2...

Страница 39: ...the Console in Away Mode clears all supervisory events for emergency sensors only Supervisory timers for Smoke detectors CO detectors and activity monitor sensors are not affected switching to Home or...

Страница 40: ...E CELL MODULE PRESENT Opening Port COM30 Initializing Com Port Sending password Login Success Get status data Console Type Standard Console Protocol Ver 5 Hardware Ver 0 Firmware Ver 2 4 0 Data Versio...

Страница 41: ...NG IP REPORTING DELAY 0 or 15 Seconds IP REPORTING FORMATS SIA CID18 Extended CID58 Extended REMOTE PROGRAMMING PASSWORD 6 Digits REMOTE COMMUNICATIONS PASSWORD 4 Digits ACCOUNT NUMBER LENGTH FIBRO IP...

Страница 42: ...a applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit ac...

Страница 43: ...ment Server Timer 21 Menu bar 13 Mode after disconnect 15 Modem connection 27 Modem testing 11 Mode setting 25 Mode switch reporting 24 Mode switch reporting setting 24 Mode table 37 N Night mode 7 16...

Страница 44: ...Copyright 2016 Nortek Security Control LLC 10007317 B...

Отзывы: