Z-WAVE PROGRAMMING
Adding to a Network
Refer to your Controller operating instructions to add this switch under the
command of the Wireless Controller
1. With your Controller in Discovery or Add Mode, press the Program Switch
for 1 (one) second. The Yellow LED will blink. The device will appear in the
list of devices and should display as (4) four items: M4IN1Z-1 (Motion),
Light Sensor, Temperature Sensor and Humidity Sensor.
If the Controller/Gateway shows the addition failed, repeat Steps 1-3.
✓
NOTE: If you have trouble adding the M4IN1Z-1 to a group it may be that
the Home ID and Node ID were not cleared from it after testing. You must
fi rst “RESET UNIT” to remove it from the network. Although adding it to a
group includes it in the network, removing it from a group does not remove
it from the network. “RESET UNIT” removes it completely from the network.
To Reset Unit (if required):
In the event that your primary Controller is lost or otherwise inoperable, to reset
the M4IN1Z-1 and clear all network information, follow these steps:
1. Remove cover to trigger the tamper switch. The LED will fl ash once and
send out Alarm Report.
2. Press Program Switch 10 times within 10 seconds. The M4IN1Z-1 will send
the “Device Reset Locally Notifi cation” command and reset to the factory
default. (Remark: This is to be used only in the case of primary controller
being inoperable or otherwise unavailable).
3. The M4IN1Z-1 will completely reset to factory defaults.
Removing from a Network:
The M4IN1Z-1 can be removed from the network by the Controller/Gateway.
Refer to the Controller operating instructions for details. Be sure to select the
M4IN1Z-1 (PIR) to remove as the other Sensors are tied to this main device.
1. With your Controller in Remove Mode, press the
Program Switch
for one
(1) second.
2. You should see an indication on your Controller that the device was removed
from the network.
Association
1. Press the program switch on the M4IN1Z-1 to initiate the “Awake” mode.
The LED will fl ash once.
2. Put your Controller into “Association,” and following its instruction to
associate the M4IN1A-1 to other devices.
Other Z-Wave Commands
Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1
week) and send the wake up notifi cation to the controller.
Battery Capacity Detection:
• Use “Battery Get” command to have the battery capacity back in %.
• It will detect the battery capacity automatically.
• Low Battery Auto Report when power is lower than 2.6V +/-0.1V.
Temperature:
If the present temperature is different than previously recorded and has
changed by more than the value in Parameter 2 (see below), the sensor will
report the present temperature to the hub. The LED will fl ash every (3) three
minutes to represent the temperature.
Temperature
LED Color
Under 59
°F
Green
60 - 73
° F
Blue
74 - 82° F
Yellow / Yellow
Green
83 - 97° F
Purple
Over 97° F
Red
Multilevel Sensor Report
Sensor Type
0x01
Scale
0x00 (°C)
0x01 (°F)
Size and Precision
2
Humidity Report:
If the present humidity is different than previously recorded and has changed
by more than the value in Parameter 3(see below), the sensor will report the
present illumination.
Light Report:
If the present illumination is different than previously recorded and has changed
by more than the value in Parameter 4 (see below), the sensor will report the
present illumination.
Multilevel Sensor Report
Sensor Type
0x03
Scale
0x00
(%)
Size and Precision
2
OPERATION
• When a person walks in from of M4IN1Z-1, the sensor will send Basic set
On (0xFF) and the Red LED will flash once. Refer to status report as table
below.
• In no movement is detected in (3) three minutes (default), it will send Basic
Set OFF (0x00) will be sent and the Red LED will flash once.
• The M4IN1Z-1 is equipped with tamper switch. If the tamper switch is
triggered ( or the cover is removed), the M4IN1Z-1 will send an Alarm
Report.
• If the tamper switch is closed (or the cover closed), the M4IN1Z-1 will send
an Alarm Report.
• Supports OTA Firmware update from the controller. Please refer to your
controller manual and use COMMAND_CLASS_FIRMWARE_UPDATE_
MD_V2. To proceed with the OTA process. Once the OTA function is
successful, make sure to exclude the device and include again before using
the device.
Figure 4.Detecting
Area
9M
TOP VIEW
SIDE VIEW
CEILING
DETECTING AREA: UNIT: METER
0
1
2
3
4
5
6
1 2 3 4 5 6M
0M
5M