Nortek GoControl LB65R6Z-1 Скачать руководство пользователя страница 4

4

Copyright © 2015 Nortek Security & Control LLC 

10007037 X7

CONFIGURATION

The LB65R6Z-1 supports the Confi guration command. The LB65R6Z-1 can be 
confi gured to operate slightly differently than how it works when you fi rst install 
it. Using the Confi guration command you can confi gure the following:

Parameter 1: Dim Level Memory

By default, the LB65R6Z-1 bulb will go to full brightness when turned on. To 
have the bulb turn on to the last dim level setting, set Parameter 1 to 1.

Parameter Length Valid Values

Confi guration Option

1

1 Byte

0

Bulb will be full brightness when turned on 

(default)

1

Bulb will turn on to the last dim level setting

Parameter 9: Dim / Bright Step Level

When the brightness is adjusted by the controller/gateway, how much the bulb 
brightness will change is set by the programmed dimming step level.

Parameter Length Valid Values

Confi guration Option

9

1 Byte

1 - 99

Default = 1

The step level is small when the value is low
The step level is large when the value is high

Parameter 10: Dim / Bright Speed

When the brightness is adjusted by the controller/gateway, how fast the bulb 
brightness will change is set by the programmed dimming step speed.

Parameter Length Valid Values

Confi guration Option

10

1 Byte

1 - 10

Default = 3

The step speed is fast when the value is low
The step speed is slow when the value is high

Example: If Parameter 9 is set to the default value of 1, setting Parameter 10 
from 1 to 10 will equal the number of seconds it takes to dim down the bulb 
when the bulb is turned off, i.e. 1 equals 1 second for the bulb to dim down and 
turn off, 10 equals 10 seconds for the bulb to dim down and turn OFF.

Z-Wave Plus Features

The LB65R6Z-1 contains a Z-Wave 500 Series Module that supports Z-Wave 
Plus features. A Z-Wave certifi ed portable or stationary controller can 
communicate with the Z-Wave 500 Series Module.

Depending on the capability of the controller or gateway software, the following 
operations can be performed with the LB65R6Z-1. Refer to the controller or 
gateway manual for details.

•  Turn the fi xture ON and OFF.
•  Dim the fi xture.
•  Add or Remove the LB65R6Z-1.
•  Assign the LB65R6Z-1 to a specific Group/Scene and/or to include the 

fixture as part of ALL ON or ALL OFF system commands.

•  Over-the-air firmware update by the gateway or static controller.
•  Lifeline function which automatically notifies the associated modules and 

the network that a manually reset device is no longer in the network, thus, 
the corresponding association becomes invalid.

INTEROPERABILITY WITH Z-WAVE DEVICES

A Z-Wave network can integrate devices of various classes of products, 
and these devices can be made by different manufacturers. The GoControl 
LB65R6Z-1 has Z-Wave certifi cation which guarantees interoperability.

ASSOCIATION

The LB65R6Z-1 supports one Group with fi ve Nodes for lifeline communication. 
Group 1 must be assigned the Node ID of the controller to which unsolicited 
notifi cations from the LB65R6Z-1 will be sent. The Z-Wave controller should 
set this association automatically after inclusion. You can associate up to fi ve 
Z-Wave devices to Group 1. Lifeline association only supports the “manual 
reset” event. 

For instructions on how to “set lifeline association” please refer to your wireless 
controller instructions.

SPECIFICATIONS

Power Supply

 

120 VAC, 60 Hz

Brightness

 650 

lumens

 

(Equivalent to 65 Watt incandescent light bulb)

Power Consumption

 8.5 

Watts

Color Temperature

 2700K

Fixture Lifetime

 25,000 

hours

 

(equivalent 22.8 years based on 3 hours/day)

Radio Frequency

 

908.4 MHz / 916 MHz

Wireless Range

 

Up to 130 feet line of sight between the Z-Wave

 

Controller and/or the closest Z-Wave Repeater

Normal Operating Temp

 77°F 

(25°C)

Repeater

 Yes

Fits Recessed Fixture Size

  5” to 6” diameter

Z-Wave® and Z-Wave Plus® are registered trademarks of Sigma Designs

and its subsidiaries in the United States and other countries.

REGULATORY INFORMATION

The LB65R6Z-1 is certifi ed to comply with applicable FCC and IC rules and regulations governing RF and EMI 
emissions.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device 
may not cause harmful interference, and (2) This device must accept any interference received, including interference 
received that may cause undesired operation.

FCC Notice

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
•  Consult the dealer or an experienced radio/TV technician to help.
•  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s 

authority to operate the equipment

IC Notice

This Class B digital apparatus complies with Canadian ICES-003

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme 
aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux 
conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout 
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to the following 
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including 
interference that may cause undesired operation of the device.

WARRANTY

This Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24) 
months based on three (3) hours of use per day. 

This warranty extends only to wholesale customers

 who buy direct 

from Nortek Security & Control or through Nortek Security & Control’s normal distribution channels. 

Nortek Security 

& Control does not warrant this product to consumers.

 Consumers should inquire from their selling dealer as to 

the nature of the dealer’s warranty, if any. 

There are no obligations or liabilities on the part of Nortek Security & 

Control for consequential damages arising out of or in connection with use or performance of this product 
or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, 
or reinstallation.

 All implied warranties, including implied warranties for merchantability and implied warranties for 

fi tness, are valid only until Warranty Expiration Date as labeled on the product. 

This Nortek Security & Control LLC 

Warranty is in lieu of all other warranties express or implied. 

All products returned for warranty service require a 

Return Product Authorization Number (RPA#). Contact Nortek Security & Control Returns at 1-855-546-3279 for an 
RPA# and other important details.

IMPORTANT !!!

Radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. 
However, there are some limitations which must be observed.

•  For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. 

As such, they have limited transmitter power and therefore limited range.

•  A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that 

occur on or near their operating frequencies, regardless of code settings.

•  Changes or modifications to the device may void FCC compliance.
•  Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
•  A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, 

and these facts should be communicated to the ultimate users. 

Отзывы: