7

Figure 9. C8QA Coil Dimensions

2 1/2”

W

19 1/2”

1 3/8”

1”

12 1/8”

14 1/2”

H

Table 1. Coil Specifications

C8QA-

024

030

036

042

Nominal Capacity (BTUH)

24,000

30,000

36,000

42,000

Nominal Airflow (CFM)

800

1,000

1,200

1,400

W - Width (in.)

18 1/8

18 1/8

18 1/8

18 1/8

H - Height (in.)

18

18

18

24 3/4

D - Depth (in.)

19 1/2

19 1/2

19 1/2

19 1/2

Connection - Liquid Line (in.)

3/8

3/8

3/8

3/8

Connection - Suction Line (in.)

3/4

3/4

3/4

3/4

Installed Orifice Size (in.)

.055

.061

.067

.072

NOTES:

1.  Individual restrictors are available by part number - PN664*** (where *** represents the size). 

Example: 664103 is a restrictor 0.103 in diameter.

2. 

Refer to sales specification sheets for Listed / Certified combinations of equipment and required accessories.

3. 

Refer to the current AHRI directory for certified ratings of split systems.

COIL SPECIFICATIONS & DIMENSIONS

Содержание C8QA Series

Страница 1: ...deciding factor when installing this product and using common sense plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper...

Страница 2: ...ditions which may result in personal injury or property damage Unless otherwise noted in these instructions only factory authorized kits or accessories may be used with this product WARNING PROPOSITIO...

Страница 3: ...safety warnings exactly could result in serious injury or property damage Improper servicing could result in dangerous operation serious injury death or property damage Beforeservicing disconnectalle...

Страница 4: ...erantlines confirmthat theorificesizemeetstherequirementsoutlined in the outdoor unit installation manual Factory installed orifice sizes are listed in Table 1 page 7 If the restrictor orifice must be...

Страница 5: ...urning the swivel nut counterclockwise 4 Insert a light gauge wire hook between the distributor body and the restrictor orifice while being careful not to scratch either part Carefully remove the rest...

Страница 6: ...overflow a separate 3 4 inch drain must be provided from the secondary drain connectionandasecondarydrainpanmustbeinstalled under the entire unit Run secondary drain lines to a place where they are n...

Страница 7: ...19 1 2 19 1 2 19 1 2 Connection Liquid Line in 3 8 3 8 3 8 3 8 Connection Suction Line in 3 4 3 4 3 4 3 4 Installed Orifice Size in 055 061 067 072 NOTES 1 Individual restrictors are available by par...

Страница 8: ...cations illustrations subject to change without notice or incurring obligations O Fallon MO Printed in U S A 02 12 709280A Replaces 7092800 INSTALLER PLEASE LEAVE THESE INSTRUCTIONS WITH THE EQUIPMENT...

Отзывы: