This Quick Guide provides you with the basic information you need to get the 
instrument up and running as quickly as possible. If you are familiar with the 
Nortek instruments, this guide may be all you need. If you are new to our 
instruments and software, you should check out the Nortek Comprehensive 
Manual (available on the web), which includes principles of operation, 
mounting guidelines, troubleshooting, service manual and simple system 
integration. You will also find much useful information in the FAQ site at the 
Nortek web: 

www.nortekgroup.com

 

Preparation 
 

•  Connect the battery/power cable. 
•  Install the software located on the USB memory stick. Once the 

installation is complete, launch the program called AWAC/AWAC AST.  

•  Run a Functional Test, described in the 

Service Manual

 chapter in the 

Comprehensive Manual. 

•  Set the Pressure Offset: 

On-line > Set Pressure Offset

•  If there are magnetic materials in proximity to the instrument when 

mounted, a calibration of the compass is necessary: 

On-line > Compass 

Calibration

•  Erase the recorder in advance of every deployment. 

 

Deployment Planning 
 

•  Select 

Deployment Planning

•  The activated dialog contains all parameters required to specify the 

operation of the instrument. The Deployment Planning frame on the right-
hand side of the dialog displays performance parameters that are 
automatically updated as you change the settings. Use the Standard 
configuration to plan your deployment unless you have a very good 
reason to move to Advanced. The latter increases the flexibility but so 
does the risk of making mistakes. Note that the Use 

Advanced Settings

 

box (in the Standard tab) must be checked for the advanced settings to be 
effective. A description of each parameter can be found in the application 
help, accessible from the dialog box. 

•  By using the Open/Save commands in the File menu (or the 

corresponding toolbar buttons) the deployment parameters can be saved 
to file at any given time and re-loaded when it is time to deploy the 
instrument. 

 

Start Recorder Deployment 
 

•  Establish communication with the instrument. 
•  Select 

Start Recorder Deployment

, either from the pull-down menu or 

from the toolbar. 

•  Specify the date and time to start the data recording.  
•  In the Name field, enter up to six characters of text to identify the data file 

stored in the recorder. 

•  In the File Comment box, enter up to 180 characters of text that will be 

included in the data file for documenting the data set. 

•  After pressing 

OK

, the Set Clock dialog box is displayed. We recommend 

setting the clock to PC time. The time reference is especially important to 
ensure proper synchronization between the instrument and other data 
sets collected independently. Time spent on setting the time properly 
before a deployment can save a lot of time in post processing and 
analysis. 

•  Press 

Yes

 to continue. A confirmation dialog will display the deployment 

parameters and allow you to verify that the set-up is what you intended. 

•  Press 

Confirm

 to send the configuration to the instrument. The instrument 

will verify that the deployment has started. The configuration information 
from the deployment sequence is saved in a log file that has the same 
name as the deployment.  

Please check that all  
expected items are  
included in the shipment: 

 

 AWAC  

 External power/signal cable 

 NORTEK equipment storage 

    box/toolkit 

 USB to serial converter 

 AC/DC 15VDC transformer 

 Power cable  

    (European or American)  

 Software on USB memory stick 

 Final test check list 

 Packing list 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install the Nortek 

software  

The instrument’s software 
is located on the attached 
memory stick.  
 
Please check the web 
regularly for updates on 
both software and firmware. 

 

 