BASIC OPERATION
Switches
The paddle on the WT00Z5-1 allows the user to:
• Turn the Associated devices on or off.
• Tapping top of switch turns the Associated device ON.
• Tapping bottom of switch turns the Associated device OFF.
Dimmers
The paddle on the WT00Z5-1 allows the user to:
• Dim the Associated devices.
• Press and Hold the top of switch to increase the intensity of the Associated
device.
• Press and Hold the bottom of switch to decrease the intensity of the
Associated device.
• Tapping top of switch turns the Associated device ON to the previously set
level.
• Tapping bottom of switch turns the Associated device OFF.
LED Indication
To act as a night light, the LED on the WT00Z5-1 will turn ON when the
Associated device is OFF. However, the LED can be user confi gured to turn
ON, when the Associated device is ON, if so desired. See “CONFIGURATION”
section.
Remote Control
The WT00Z5-1 will respond to BASIC and BINARY commands that are part of
the Z-Wave system. Refer to your Controller’s instructions as to whether your
Controller can transmit those commands.
Associations
The GoControl WT00Z5-1 supports three (3) Association Groups. Group
1 is the “Lifeline” group and must be assigned the Node ID of the Z-Wave
Controller to which unsolicited notifi cations from the WT00Z5-1 will be sent.
Group 1 supports a single Node ID. The Z-Wave Controller should set the
Lifeline Association automatically after inclusion. For instructions on how to
set Associations, please refer to your Z-Wave Controller instructions. Group
2 nodes will be sent BASIC On/Off commands and is intended to control
switches like the GoControl WS15Z5. Group 3 nodes will be sent Multilevel
Switch commands and is intended to control dimmers like the GoControl
WD500Z5. Groups 2 and 3 support up to fi ve (5) Node IDs.
Associations can be created automatically without requiring the Z-Wave
Controller.
Creating Associations
1.
Learn all devices into the Z-Wave Hub.
2.
Tap the paddle of the WT00Z5-1 four times quickly to enter Association
mode. The LED will begin to blink quickly (twice per second).
3.
Follow the instructions for inclusion or exclusion of the device to be
associated. For GoControl devices, tap the button two times.
4.
Repeat Step #2 and #3 for up to 5 total dimmers and / or switches within 60
seconds of entering Association mode.
5.
Association mode will turn off after 60 seconds or when a node has been
associated.
Although the Associations are now functional, it is recommended that you
refer to your Hubs instructions to “Heal” the Z-Wave network to recognize the
new Associations. Dimmers are automatically assigned to group 3 and other
devices are assigned to group 2.
Removing Associations
To remove the Associations, if the Hub has recognized the Associations, refer
to the Z-Wave Hub’s instructions on how to remove Associations. If the Hub
has not recognized the Associations, removing the WT00Z5-1 from the Z-Wave
network will eliminate the Associations.
CONFIGURATION
The WT00Z5-1 supports the Confi guration command.
The WT00Z5-1 simulates the operation of a dimmer. Using confi guration
commands you can adjust the dimming parameters as though it were a
dimmer. The WT00Z5-1 can be confi gured to operate slightly differently than
how it works when you fi rst install it. Using the confi guration command you can
change operational characteristics.
Night Light
The Z-Wave BASIC Command Class can control or report the state of LED.
The state of the LED depends on the value in Parameter 3.
By default, the LED on the WT00Z5-1 will turn OFF when the Associated
device is turned ON. To make the LED turn ON when the Associated device is
turned ON, set Parameter 3 to a value of 1.
Parameter Length Valid Values
Confi guration Option
3
1 Byte
0
LED OFF when the load is on, and ON when the load
is off
(default - night lite mode)
1
LED ON when the load is on, and OFF when the
load is off
2
LED is always on
3
LED is always off
4
LED blinks during RF transmissions from or to the
device
Invert Switch
To change the top of the switch to OFF and the bottom of the switch ON, set
Parameter 4 to a value of 1.
Parameter Length Valid Values
Confi guration Option
4
1 Byte
0
Top of switch is ON, bottom of switch is OFF
(default)
1
Bottom of switch is ON, top of switch is OFF
Over-The-Air (OTA) Update
Firmware of the WT00Z5-1 can be updated at any time. Follow the instructions
in your Z-Wave Hub to send the updated fi rmware. The LED “winks” twice per
second indicating it is in fi rmware update mode.
Resetting to Defaults
Each confi guration Parameter can be set back to its default setting by setting
the default bit in the Confi guration Set command. See your Controller’s
instructions on how to do this (and if it supports it). All confi guration commands
will be reset to their default state when the WT00Z5-1 is excluded from the
Z-Wave network by using the Controller to reset the node.
SPECIFICATIONS
Power:
120 VAC, 60 Hz
Signal (Frequency):
908.42 MHz / 916 MHz
Maximum Load:
None
Range:
Up to 130 feet line of sight