background image

 

 
 
 

 

 

 

 

HEAD OFFICE 

FACTORY 

VCCE Office Park 

32a Wiganthorpe Rd   

170 Peter Brown Dr 

Willowton 

 

 

Pietermaritzburg 

Pietermaritzburg 

3201 South Africa 

3201 South Africa                            

Tel:  +27 33 260 2700 

Tel:  +27 33 345 3456 

Fax: +27 33 260 2701 

Fax: +27 33 394 6449 

 

PO Box 4099 

www.nortech.co.za

 

  

Willowton Hub 

[email protected]

 

 

3200 South Africa 

Nortech International (Pty) Ltd. 

Reg. No. 1998/010951/07

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PD17x 

Single Channel parking Detector 

User Manual 

 

 
 
 
 
 
 
NORTECH INTERNATIONAL (PTY) LTD 
All rights reserved 
Copyright © 2016 
Document Number: 307UM0100_01 
Date of Issue: May 2016

 

 
 

This document is for information only and unless otherwise indicated, is not to form part of any contract.  In 

accordance with the manufacturer’s policy of continually updating and improving design, specifications 

contained herein are subject to alteration without notice. 

 

Содержание PD17x

Страница 1: ...South Africa Nortech International Pty Ltd Reg No 1998 010951 07 PD17x Single Channel parking Detector User Manual NORTECH INTERNATIONAL PTY LTD All rights reserved Copyright 2016 Document Number 307U...

Страница 2: ...ments 14 5 2 Operational Constraints 14 5 3 Loop and Feeder Material Specification 15 5 4 Sensing Loop Geometry 16 5 5 Loop Installation 16 6 Configuration 18 6 1 PD171 Enhanced Detector Order number...

Страница 3: ...e barrier area during installation and testing that may result in unexpected operation of the barrier WARNING 6 USA FCC Advisory Statement Refer to Appendix A at the end of this document WARNING 7 Eur...

Страница 4: ...tallation and convenience with automatic frequency selection to assist with installation as well as customisable outputs and operating modes the product is easily configurable to suit various applicat...

Страница 5: ...detect Relay 2 operates as a pulse relay activating on an event as specified by the switches Pulse Output Duration User selectable to either 150ms or 250ms Presence Method Permanent or Limited presenc...

Страница 6: ...t temperatures above 60 C de rate the relay Maximum current as per graph below 2 3 Environmental Data Storage Temperature 40 C to 80 C Operating Temperature 40 C to 80 C Humidity Up to 95 relative hum...

Страница 7: ...o the DIN Rail and is fitted with 2x 6 way connectors for wiring the necessary connections Figure 2 PDx7x rear view showing the 11 pin connector on the left and the DIN Rail housing on the right Relay...

Страница 8: ...matic Frequency Selection AFS switch 7 This setting allows the detector to briefly evaluate all five frequency bands and select the best operating frequency available The tuning time with AFS switched...

Страница 9: ...Powerfail If the LEDs are ON Powerfail is ON If the LEDs are OFF Powerfail is OFF Power fail toggle 30 sec Holding for 30s will toggle the Powerfail status The state of Powerfail is known after holdi...

Страница 10: ...should be noted however that the Channel LED does NOT necessarily represent the output state of the relays It only represents the detection of a vehicle over the loop The relay state could for example...

Страница 11: ...uctance in the range 20 to 1500 micro henries H This wide range ensures that all loop sizes and feeder combinations will be accommodated in the tuning range of the detector Once tuned any slow environ...

Страница 12: ...N C Idle Open Closed On Event Closed Open Fault Open Closed Power Off Open Closed Figure 6 Pulse Relay output configuration options In fail safe the output is the same in detect as it is with no power...

Страница 13: ...hall NOT be opened when the unit is OFF and Powerfail is turned on as any drastic change in temperature could result in Powerfail starting up in the incorrect state Nortech accepts no responsibility o...

Страница 14: ...etic Circuit Breaker for AC models and a fuse for DC models v WARNING This product must be installed in an enclosure as the IP rating of the detector is IP 30 vi WARNING No user serviceable parts insi...

Страница 15: ...The slot depth should be kept as shallow as possible taking care that no part of the loop or the feeder remains exposed after the sealing compound has been applied 5 3 Loop and Feeder Material Specif...

Страница 16: ...uments INDUCTIVE LOOP VEHICLE DETECTION Nortech Doc No MKT0001 TRAFFIC DETECTION Nortech Doc No MKT0002 PARKING APPLICATIONS MANUAL Nortech Doc No MKT0003 LOOPS and LOOP INSTALLATION Nortech Doc No MK...

Страница 17: ...17 of 31 Figure 7 Adjacent loops connected to different detector modules Figure 8 Slot details 300 mm 300 mm 2 m depending on road width 1 m 1 m Min Distance Apart 2 m Road width 2 m 3 m Road width 4...

Страница 18: ...Order number 307FT0103 301FT0041 Wiring Harness Wire COLOUR 11 PIN Connector Pin No FUNCTION Red 1 Live Power supply 120V AC 10 50 60Hz Black 2 Neutral Grey 3 N O Pulse Contact Violet 4 Common Pulse...

Страница 19: ...9 Earth Pink 10 N C Presence Contact White 11 N C Pulse Contact Figure 9 Example of PD17x side labels Power supply requirements and pin connections are clearly stated on the side of the unit 11 Pin c...

Страница 20: ...nnected Bottom 7 N C Pulse Contact 8 Common Pulse Contact 9 N O Pulse Contact 10 N C Presence Contact 11 Common Presence Contact 12 N O Presence Contact 6 6 PD174 Enhanced Detector DIN Rail Order numb...

Страница 21: ...307UM0100_01 May 2016 PD17x User Manual Page 21 of 31 11 Common Presence Contact 12 N O Presence Contact...

Страница 22: ...To arm card readers and ticket dispensers As a barrier gate door closing detector As a barrier gate door opening detector Free exit To generate pulses for vehicle counting The features that make the...

Страница 23: ...the loop output LED flashes intermittently and the relay chatters The loop is getting spurious detects due to a Crosstalk with adjacent detector b Faulty loop or feeder connection a Change frequency s...

Страница 24: ...he loop coil The following will happen on detection The OUTPUT LED will light up Output relays set to PRESENCE on that channel will operate Output relays set to PULSE will operate momentarily To check...

Страница 25: ...equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one...

Страница 26: ...degree 2 Appendix B 2 IEC 60950 22 2005 Northern Europe To achieve outdoor operation down to 50 C as required by IEC 60950 22 2005 for Northern Europe Finland Norway and Sweden a heater with a thermo...

Страница 27: ...____________________________ Telephone No _______________________ Mobile Cellphone No _________________ FAX No ____________________________ Postal address ____________________________________ ________...

Страница 28: ...___ If AC then the Frequency _______ Hz LOOP DETAILS Channel 1 Size of loop ____ m by ____ m Shape of loop _____________________ Number of Turns _____ Size of wire used mm2 or AWG _____________ Type o...

Страница 29: ...of insulation _____________ mm Type of feeder cable used screened armoured multicore etc ____________________________________________________________________________________________ __________________...

Страница 30: ...eeder cable __________ V AC voltage between one of the feeder cable wires and earth __________ V DC resistance of Feeder plus Loop _______ ohms Inductance of Feeder plus Loop ________ H Frequency of m...

Страница 31: ...Change for each vehicle type Use the maximum sensitivity reading and reset the statistics between each reading Vehicle Type Channel 1 Inductance Change Bicycle L L Motorbike L L Car L L SUV L L Artic...