NanoQuest Simple Installation Guide
DOC0053_Issue2.2
Operating the NanoQuest
When a valid User card is presented to the reader in operating mode, the buzzer beeps once and
the strike relay operates. The LED glows green while the strike relay is active.
To activate the auxiliary output, an Auxiliary card must be presented to the unit 3 times. The buzzer
beeps once for each presentation and give two additional beeps to confirm activation of the
auxiliary output. Repeat the process to deactivate the auxiliary output (in default mode).
Wiring Information
Colour
Function
Colour
Function
Red
+ve (9 to 16V DC, 100mA)
Green
Auxiliary out, 500mA open collector
(or Wiegand Data 0)
Black
Ground
White
Wiegand Data 1
White/Black
Request to Exit button
Blue
Local alarm output, 500mA open
collector.
Orange
Door contact input (open
when door is open)
Red/Black
Auxiliary in/arming (see below)
Orange/Black Relay common
Green/Black RS232 serial data
Green/White
Normally open contact
Blue/Black
Wiegand mode select (connect to
+VE for Wiegand)
Blue/White
Normally closed contact
Specifications
Number of users:
500
Door Open time:
0.5 to 10 seconds, plus Latch mode (e.g. for secure control of equipment)
Aux out:
Latch or Pulse after 3 shows of selected cards
Aux in:
Open for reading, connect to ground to disable latch
Door Monitoring:
Connect to ground for door closed, open for door open. Allows door forced and
door left open alarms. Also re-locks door immediately when door is opened.
Silent Mode:
Card detection is silent (does not affect programming and audible alarm).
Power requirements:
9-16V DC, 70mA (unit only)
Relay rating:
1A @30Vdc
Operating Temp:.
-20C to +55C
IP Rating:
IP65 - suitable for internal and external use
Read Range:
Up to 80mm, depending on Token used
Dimensions:
111 x 49 x 19 (H x W x D)
If you can’t find the information you require in this document or in the full Instruction Manual, then