125KHz Reader Wiring
Connect the reader cable to the reader port of the controller according to
the table below. For readers with a screw terminal block, refer to terminal
numbering diagram.
Terminal*
Cable
Function
1
Red
+5VDC to +16VDC
2
Black
Ground
3
Yellow
Green LED input
4
White
Wiegand Data 1 / Clock
5
Green
Wiegand Data 0 / Data
8
Brown
Beeper input
9
Orange
Format Select (see below)
10
Blue
Serial Data Output
Format Select:
Use the ‘Format Select’ lead to set the required data output
format by connecting it to either Ground or +VDC as follows:
Reader Variant
Connect to ground
Connect to +VdC
EM1, HT1
10-Digit Clock & Data
26-Bit Wiegand
DP1
26-Bit Wiegand
44-Bit Wiegand
1 2 3 4 5
9
8
7
6
13
12
11
10
*Terminal
Numbering