ReadeR WiRing inSTRUCTiOnS

DOC0067 Issue 1.0

125kHz reader models with 
the following prefixes:

 13.56MHz reader models 
with the following prefixes: 

MP1-EM1 
MP1-HT1 
MP1-DP1 
WP1-EM1 
WP1-HT1 
WP1-DP1

SP1-EM1 
SP1-DP1 
SP1-DP1 
WP2-EM1

MP1-LEG 
MP1-MIF 
MP1-ISO

WP1-LEG 
WP1-MIF 
WP1-ISO

SP1

MP1

WP2

WP1

Содержание MP1

Страница 1: ...0 125kHz reader models with the following prefixes 13 56MHz reader models with the following prefixes MP1 EM1 MP1 HT1 MP1 DP1 WP1 EM1 WP1 HT1 WP1 DP1 SP1 EM1 SP1 DP1 SP1 DP1 WP2 EM1 MP1 LEG MP1 MIF MP1 ISO WP1 LEG WP1 MIF WP1 ISO SP1 MP1 WP2 WP1 ...

Страница 2: ...reen LED input 4 White Wiegand Data 1 Clock 5 Green Wiegand Data 0 Data 8 Brown Beeper input 9 Orange Format Select see below 10 Blue Serial Data Output Format Select Use the Format Select lead to set the required data output format by connecting it to either Ground or VDC as follows Reader Variant Connect to Ground Connect to VDC EM1 HT1 10 Digit Clock Data 26 Bit Wiegand DP1 26 Bit Wiegand 44 Bi...

Страница 3: ...iegand Data 1 Clock 4 Green Wiegand Data 0 Data 5 Yellow Green LED input 6 Brown Beeper input 7 Blue Serial Data Output 8 Orange Format Select see below Format Select Use the Format Select lead to set the required data output format by connecting it to either Ground or VDC as follows Reader Variant Connect to Ground Connect to VDC ISO 10 Digit Clock Data 32 Bit Wiegand MIF LEG Dependant upon the c...

Страница 4: ...ure that the card is accepted and the LED and beeper respond to the access controller as expected This will depend upon how you have wired the reader and the way in which the access controller operates If the card details are not recognised by the access controller check all connections and ensure that you have connected the Format Select input correctly according to the table in the wiring instru...

Страница 5: ... colour LED red green Beeper Dual colour LED red green Red LED Green LED Beeper IP Rating IP65 Operating Temperature 20o C to 50o C For further details view or download the corresponding product datasheet from the Nortech website at http www nortechcontrol com document library aspx Product mounting templates are also available at this location ...

Страница 6: ...sure that the cover securing screw is not fitted to the base of the reader and separate the front cover and the reader body as follows Insert the tip of a terminal screwdriver into the small slot in the base of the cover Press lightly to release the securing catch while you separate the cover from the reader at the base ...

Страница 7: ...l and mark out the position of the fixing holes drill and prepare the holes Terminate the cable conductors according to the wiring details overleaf If the reader is fitted with screw terminals position the reader against the mounting surface ensure that the reader is level and mark out the position of the fixing holes Drill and prepare the fixing holes Feed the connecting cable through the cable h...

Страница 8: ... is fitted with a cable feed the cable through the hole in the back box to the controller and terminate the conductors according to the wiring details overleaf If the reader is fitted with screw terminals feed the connecting cable into the back box and terminate the conductors according to the wiring details overleaf Secure the reader to the back box using the screws supplied Note To fit the Flush...

Страница 9: ...re is the same for the wall switch model Hook the two tabs at the top of the reader cover over the top of the 1 reader back plate engaging them with the corresponding slots in the back plate Hinge the cover over the reader body until it is correctly seated over 2 the reader it should click into place Insert the cover retaining screw in the base of the reader and tighten 3 1 2 3 ...

Страница 10: ...e cable through the wall and terminate it either at the access 3 controller or in a suitable terminal box Screw the reader to the wall using the screws provided and 4 appropriate plugs fixings not supplied for the type of mounting surface Terminate the conductors according to the wiring details overleaf 5 Fit the label once the reader has been fully installed and you are 6 confident that the unit ...