![Nortec WB120 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/nortec/wb120/wb120_installation-manual_1705758019.webp)
19
Trouble
Possible reason
Solving method
Burner does not start after
start-up or works
inconsistently giving out an
error
Primary air pressure in line 1
is set beyond recommended
value.
Regulate primary air pressure value according to
section 7.
Fuel does not heat up to
necessary temperature.
Increase fuel heating temperature value according
to section 8.
There is too much moisture in
the fuel.
Let the fuel stand before use. Adjust the floating fuel
inlet according to section 11.
There are mud or solid dregs
in the fuel.
Replace the filtering element according to section
11. Clean the fuel box, let the fuel stand and adjust
the floating fuel inlet according to section 11.
There is too much synthetic
oil in the fuel.
Add some mineral oil into the fuel. It should be 30%
fuel, 70% mineral oil.
or
Add 10-20% of diesel to the fuel volume.
Fuel does not ignite properly.
Check the fuel. Replace it or add diesel. Combine
proportion experimentally.
Littered sieving filter in the
preliminary fuel heating box.
Clean the filter. Replace the filtering element of the
lifting unit. Clean the heater box from dregs and
soot.
Moisture in the preliminary
heating box.
Pour moisture out via drain tap 17 (pic.3). Adjust a
floating fuel inlet according to section 11.
Littered nozzles.
Use an authorized service center NORTEC to clean
the nozzles.
Clean the fuel system thoroughly, replace a filtering
element of the lifting unit.
Fuel does is not delivered to
the preliminary heater box
Lifting unit pump is not
connected.
Check the connection and connect the pump
according to section 13.
No fuel in the main fuel box.
Add fuel to the box.
Littered fuel inlet.
Clean the fuel inlet, clean the fuel box from dregs
and moisture, set the floating fuel inlet according to
section 11.
Fine cleaning filter is
exhausted.
Replace the filtering element according to section
11.
Fuel tube is pinched.
Remove the pinch.
The float is hung up in the
heater box.
Release and work on the float. Clean the box from
dregs and resin.
The lifting unit and burner are
too far from each other.
Move the fuel box closer to the burner or set up
another box next to the burner. Make the fuel line
cross section bigger.
Fuel flows out via the drain
hole of the heater box
Fuel is heated up too much.
Turn down the temperature of fuel heating
according to section 8.