Nortec AF-22
52002_A_EN_1611
15
5.5
Material specification
5.5.1
Protective tube
Insulating material tube (protective tube)
PG 16/PG 29
Material:
PVC-U
Complies with:
DIN 49016, Part 2, DIN 16929, DIN 4102
Temperature Range:
23°F - 140°F
Quick clamps
Material:
Polypropylene
Temperature Range:
-22°F - 194°F
Suitable for protective tube and for wall mounting.
5.5.2
Air tube and water tube
PU 4 tube, black
(water side)
Material:
Polyurethane
6 x 4 x 1 mm
Max. operating pressure:
145 psi at 68°F
PU 9 tube, blue
(air side)
Material:
Polyurethane
12 x 9 x 1.5 mm
Max. Operating pressure:
101 psi at 68°F
Plastic coupling pieces
Material:
POM
Pressure range:
0 - 10 bar
Temp. range:
14°F - 140°F
Suitable for PU tube, black and blue.
5.5.3
Cables
Type 1
Use:
Voltage supply from domestic mains to external transformer
Description:
H05 W-F 2 x 1.5 mm
²
Fusing (domestic mains):
10A, slow-to-blow
Type 2
Use:
From external transformer to atomizers and/or group control unit.
From group control unit to atomizers, in addition.
Description:
H05 W-F 2 x 2.5 mm
²
Fusing (in transformer):
2.5A, slow-to-blow