ATOM Ku GaN 20-40-80W BUC &
SSPA
052910
26
052910_rA - Operator Manual for ATOM Ku
GaN Series 20-40-80W
To change the device’s Gateway Address:
setip gw <Gateway Address><CR>
where
Gateway Address
is the new Gateway Address to use for the device.
Example command and corresponding response:
setip gw 192.168.77.1<CR>
<CR><LF>ok<CR><LF>
R
ECOVERING THE
ATOM-S
ERIES
D
EVICE
’
S
IP
A
DDRESS
If the ATOM-
series device’s IP Address, Subnet Mask, or Gateway Address is lost, each of the settings
can be recovered using the device’s Command Line Interface. Ensure that a serial connection has been
made to the device (refer to Figure 2-12 Setup Serial Port for details), and then use a terminal program or
Norsat’s ATOMControl software to send the appropriate command to the device.
To get the device’s Ethernet settings:
getip<CR>
The corresponding response
<CR><LF>ok ip <IP Address> mask <Subnet Mask> gw <Gateway
Address><CR><LF>
where
IP Address
is the device’s IP Address,
Subnet Mask
is the device’s Subnet Mask, and
Gateway Address
is the device’s Gateway Address.
Example command and corresponding response:
getip<CR>
<CR><LF>ok ip 192.168.77.100 mask 255.255.255.0 gw
192.168.77.1<CR><LF>
A
CCESSING
ATOMC
ONTROL
™
W
EB
I
NTERFACE
The
ATOMControl™ Web Interface is accessible through any web browser such as Mozilla Firefox
(recommended), Google Chrome (recommended), or Microsoft Edge. To access the web interface,
launch the web browser and type in the IP Address for the ATOM:
A simplified version of the ATOMControl software will load in the browser window.