Magic 1000

   

Please note:

 Check that the door is working properly 

and running smoothly, and adjust if necessary. The 

spring tension of the door must be set in such a way that it is 
stable and can be opened and closed by hand smoothly and 
without jolting.

• Standard and appropriate

 

shock-proof socket approx. 10 - 

50 cm away from the fastening position for the head of the 
operator.

(For information on fuses, see the technical data.)

• Only install the door operator in dry garages.

Make sure the installation set for the connection is ready on 
the door type that is being attached and/or install it according 
to the relevant manual.

See instructions for installation on page ff 162.

The head of the operator can be turned by 90° to the rail 
runner respectively as required (see page 162 (A)).

Installation step 

D, page 163:   

1. Tighten the toothed belt’s clamping nut until the toothed 

belt no longer rests on the guide rail (equivalent to 
dimension X).

2. Use the clamping nut (dimension B) to increase the 

toothed belt tension to correspond to the length of the door 
operator.

Installation step 

G, page 165, installation dimensions:

Once installation is complete

• Slowly open the door by hand until you hear the slide snap 

in.

• Connect to mains, display shows L4 and the door operator 

lamp flashes at intervals of 4.

• Teach in the door operator (see Chapter 15).
• Teach in the remote transmitter (see Chapter 16).
• Carry out a safety inspection (see Chapter 9).

ATTENTION: No protection is provided by the load 
switch-off whilst the door operator is being taught 
in. 

Note

: Teaching in is only possible during initial installation or 

after resetting the door operator. Do not press any keys 
during the teach-in procedure.

Preparation

: Connect the door to the door operator.

Teaching in with a remote transmitter

At the time of delivery and after resetting the door 
operator, the remote transmitter supports the following 
functions:

• A Safety control operation and fine adjustment "OPEN"
• B Safety control operation and fine adjustment "CLOSE"
• C and D Confirmation (storage)

Once the door operator has been taught 
in, key A is used for remote control and 
the other keys can be used to control 
other similar door operators or other 
radio receivers.  

Teaching in

• Press and hold down key A; the door 

moves in the open direction. 

• When you reach the desired 

end position "OPEN"

, release 

key A. (You can make corrections with key B.)

• Press key C once briefly, teach-in procedure: The

 

door 

operator automatically stores 

"End position OPEN/CLOSE" 

and the loads of the 

"Travel path OPEN/CLOSE"

. The door 

operator lights flash in synchronism.

Teach-in is complete when the door is open and the door 
operator lights are on. 

Check load switch-off according to Chapter 9,Safety 
inspection.

Teaching in without a remote transmitter

On the door operator:

• Press and hold pushbutton

 and the door moves in the 

open direction. Release pushbutton when the desired 
opening position is reached. A correction can be made with 
the pushbutton

.

• Press the Menu pushbutton

, the door operator 

automatically stores 

"End position OPEN/CLOSE" 

and the 

loads of the 

"Travel path OPEN/CLOSE"

 . The door 

operator lights flash in synchronism.

Teach-in is complete when the door is open and the door 
operator lights are on. 

Check load switch-off according to Chapter 9,Safety 
inspection.

Programming the remote transmitter:   

During one of the 3 status messages A, B or C (seeChapter 
10), press the pushbuttons

and

 simultaneously 

(approx. 1 s), F0 flashes in the display.
Select the desired function with the pushbuttons

and

.

Press the desired key on the remote transmitter, the radio 
command is taught in.

Note: 

The number of the function is shown in the display 

during the transmission pulse.

12 Installation preparations

13 Installation

Overhead Sectional Doors

Fig

.

Low lintel

Dimension G

Euro

30 - 50mm G2

G60

20 - 40mm G3

G60 Max

30 - 50mm G1

Normal lintel
Euro

100 - 120mm G2

G60

100 - 120mm G3

G60 Max

100 - 120mm G1

One-Piece-Door

20 - 40mm G4

14 Commissioning

15 Teaching in the door operator

16 Teaching in/deleting a remote 

transmitter

Functions

F0 OPEN / Stop / CLOSE 
F1 OPEN / Stop / OPEN
F2 CLOSE / Stop / CLOSE
F3 Stop
F4 Partial opening
F5 Light ON (restart light time) 
F6 Light ON / OFF
F7 OPEN
F8 Close

Содержание Magic 1000

Страница 1: ...ch brán DK Garageportmotor GR Μηχανισμός κίνησης γκαραζόποτρας NO Garasjeportåpner ES Accionamiento de la puerta de garaje FI Ovikoneisto PT Automatismo para portões de garagem NL Garagedeuraandrijving BG Задвижване на гаражна врата IT Motorizzazione per garage HR Pogon garažnih vrata HU Garázskapu hajtómű RO Acţionare poartă de garaj RU Привод гаражных ворот AE ΕΎΟ ήΠϟ ΕΎΑ ϮΑ ϚϳήΤΗ ϡΎψϧ N000925 1...

Страница 2: ...s or attachments Use of parts other than factory authorised replacement parts Repairs performed by persons or businesses that have not been authorised by the manufacturer If approval is not obtained for any of the above this may invalidate the product s guarantee We will not be liable for damage Due to non compliance with operating instructions Due to technical errors in connecting the door operat...

Страница 3: ... rail optosensor EMERGENCY stop connection Connection of a switch optional to an inset door mounted in the garage door for example Emergency release see page 168 J Checking load switch off The automatic load switch off is a clamping and safety mechanism that is designed to prevent accidents due to a moving door Stop the door from outside with both hands at waist height When closing The door must s...

Страница 4: ...fine adjustment CLOSE C and D Confirmation storage Once the door operator has been taught in key A is used for remote control and the other keys can be used to control other similar door operators or other radio receivers Teaching in Press and hold down key A the door moves in the open direction When you reach the desired end position OPEN release key A You can make corrections with key B Press ke...

Страница 5: ...ion Teach the door operator in again before re commissioning For this carry out Teaching in the door operator Chapter 15 17 Operation 18 Programming Factory setting Menu Function setting range unit A0 Length SOFT RUN OPEN in 7cm 000 009 002 A1 Length SOFT RUN CLOSE in 7cm 000 009 004 A2 Soft running speed CLOSE mm s 000 50 009 140 005 A3 Backjump OFF 000 ON 001 001 A4 Change in direction OFF 000 O...

Страница 6: ...nd store it Plug on safety device Additional lighting Connection must be performed only by qualified electricians In addition to the operator light 40W optional lighting of a maximum of 60 W no tubular fluorescent lamps can be connected to terminals 1 and 2 Note Some energy saving lamps can interfere with the radio signal External pulse input An external pulse signal e g wall button can be connect...

Страница 7: ...se only leak proof batteries Make sure the polarity is correct Dispose of used batteries in an environmentally friendly way 22 Troubleshooting Error messages 002 EEprom data 003 Current measurement 004 Hardware Photo cell 005 Switch off thyristors 006 Switch off relay 007 Watchdog test 008 ROM test 009 RAM test 010 SD test Description Possible cause Remedy Door operator light flashes evenly The do...

Страница 8: ...technicians Dispose of the device according to environmental guidelines Electrical parts must not be disposed of as domestic waste 2002 96 EG WEEE 23 Maintenance intervals 24 Declaration of conformity 25 Technical data Mains connection 230 V 50 60 Hz Device fuse 2x 1 6 A T slow blow Power consumption at rated load 170 W Closed current 2 W Degree of protection For dry rooms only IP 20 Protection cl...

Страница 9: ...162 214 N000925 12 2010 Magic 1000 A B C 2 1 ...

Страница 10: ...Magic 1000 N000925 12 2010 163 214 D E F A B X 1 1 2 Amm 3 492 4 580 5 668 7 844 4 6 6 9 9 11 12 15 Bmm 0 35 cm 3 492 mm 4 580 mm 5 668 mm 7 844 mm ...

Страница 11: ...164 214 N000925 12 2010 Magic 1000 G A B 5 15 mm C 100 mm B C B C A 150 mm A 150 mm ...

Страница 12: ...Magic 1000 N000925 12 2010 165 214 Einbaumaße D G3 G2 D D G4 D G1 N001452 ...

Страница 13: ...166 214 N000925 12 2010 Magic 1000 H A A 100 150 mm A 150 350 mm ...

Страница 14: ...и ворот имеется опасность вследствие отсутствия торможения при движении ворот PL Zamontować kształtownik do mocowania bramy X pasujący do typu bramy Jeżeli garaż nie posiada drugiego wejścia należy zainstalować zewnętrzne otwieranie awaryjne SI Montirajte priključni profil vrat X primeren za vrata Če je odpiralni mehanizem v sili aktiviran obstaja nevarnost pomikanja vrat brez zaviranja CZ Namonto...

Страница 15: ...ové otvorenie interné DA Intern frikobling GR Απασφάλιση ανάγκης εσωτερικά NO Innvendig nødsperre ES Desbloqueo de emergencia interno FI Sisällä oleva hätävapautin PT Desbloqueio interno de emergência NL Noodontgrendeling intern BG Вътрешно аварийно деблокиране IT Sblocco di emergenza interno HR Otključavanje u nuždi od unutra HU Belső vészkireteszelő RO Deschiderea de siguranţă internă RU Аварийн...

Страница 16: ...Magic 1000 N000925 12 2010 169 214 Lieferumfang 9 9 10 10 4 1 4 3 4 2 6 5 2 B 6 1 2 1 3 1 9 1 11 1 4 8 1 6 1 12 1 5 1 8 1 1 ...

Страница 17: ...ó podem ser substituídas por pessoal técnico autori zado BG Отбелязаните с резервни части могат да се заменят само от упълномощени специалисти HR Mijenjanje sa označenih rezervnih dijelova dopušteno je samo ovlaštenom stručnom osoblju RO Piesele de schimb marcate cu pot fi schimbate doar de către personal de specialitate autorizat AE ΓΪϤΘόϣ ΔμμΨΘϣ ΔϴϨϘΗ ΔϟΎϤϋ ΔϣϼόΑ ΓΰϴϤϤϟ έΎϴϐϟ ϊτϗ ϻ ΎϫήϴϴϐΘΑ Ϥδϳ ...

Страница 18: ...Magic 1000 N000925 12 2010 171 214 Sicherung wechseln Sicheung wechseln 1 2 3 4 5 S1 S2 ...

Страница 19: ...sed standards applied DIN EN ISO 12100 1 2004 04 Safety of machinery basic concepts general principles for design Part 1 DIN EN ISO 12100 2 A1 2009 10 Safety of machinery basic concepts general principles for design Part 2 DIN EN ISO 13849 1 2008 12 Safety of machinery Safety related parts of control systems Part 1 DIN EN 12445 2005 05 Industrial commercial and garage doors and gates Safety in use...

Страница 20: ...asic concepts general principles for design Part 1 DIN EN ISO 12100 2 A1 2009 10 Safety of machinery basic concepts general principles for design Part 2 DIN EN ISO 13849 1 2008 12 Safety of machinery Safety related parts of control systems Part 1 DIN EN 13241 1 2004 04 Industrial commercial and garage doors and gates Product standard Products without fire resistance and smoke control characteristi...

Отзывы: