SURELOK MANUAL 2002
31
MAINTENANCE - PRESSURE ADJUSTMENTS
1)
Supply the machine with 125 PSI (max) 80 PSI (min) clean dry air. We recommend
a 1/2" (min) air line at 120 psi.
2)
The inlet pressure regulator must be set as follows;
Medium Duty tooling
100 PSI.
Light Duty tooling
80 PSI.
3)
If aluminum is to be joined, the regulator can be lowered by 20 PSI.
MAINTENANCE - FILTER DRAINING
1)
There is only one air filter that will require draining.
2)
The inlet filter will collect any air contaminates that have collected in the air tank. If
filter requires draining other than daily then the inlet air is contaminated. It may be
necessary to install an extra inlet filter before the air tank.
3)
There is a small filter on the exhaust of the foot pedal.
If the filter becomes blocked the press may not return when the foot pedal is
released.
This filter should be replaced (not cleaned) if it becomes blocked.
4)
The breathers on the rear of the "WAMP" units and the breather on the front of the
barrel should not require cleaning or replacing under normal use.