Страница 1: ...The self contained refrigeration system located on the side of the cabinet requires free air access for proper operation There must be a minimum four inch clearance between the sides of the compressor...
Страница 2: ...the evaporator tubing and expelled through the condensing unit It is important that the flow of air through the side louvers is not restricted in order to ensure the condensing unit operates properly...
Страница 3: ...accomplish this remove the louvered panel from the cabinet and use a wire brush to loosen any dirt particles that are attached to the fins Use a vacuum cleaner to remove the loosened particles Failure...
Страница 4: ...pressor runs fine but 1 Overload protector 1 Check wiring diagram short cycles 2 Cold control 2 Differential too close widen 3 Overcharge 3 Reduce charge 4 Air in system 4 Purge and recharge 5 Underch...