Troubleshooting-1
Check for an Error Code on the Display Window or Optional Remote Controller
Flashing
Contact Noritz America if:
• Any other error code appears.
• An error code is indicated again after the above actions were followed.
• There are any other questions.
If there is a problem with the unit, a numerical error code will
flash on the display window or optional remote controller.
If this occurs, take appropriate measures as listed below.
When an error code appears, the display and the
operation light will flash together.
Optional Remote Controller
Display Window
Remote Controller
Cause
Action
Error Code Error Code
Ignition error.
Check whether the gas valve is open. Unplug
the unit from power or press the power button
on the optional remote controller to turn the
unit off, open a hot water fixture, and turn the
unit back on. If the flashing number doesn’t
return, the problem is solved.
Abnormal combustion.
If the display continues, contact the nearest
Noritz agent.
Abnormal combustion,
low gas supply pressure.
Have a professional check the gas supply pressure.
Contact the nearest Noritz agent.
Abnormal combustion.
Contact the nearest Noritz agent.
The unit detects Scale Build-up
in the Heat Exchanger.
(Warning indication, and
then the unit will shut off
before long.)
When the error code is flashing in the Display Window, a warning indication will
appear in the Display Window. And then the unit may shut off and lock before long.
Needs to be flushed the Heat Exchanger to remove the Scale Build-up.
If the unit will shut off and locked for this error, the unit can temporarily operate
by disconnecting electrical power until the Heat Exchanger can be flushed.
Contact Noritz America for more information about flushing the Heat
Exchanger. (866-766-7489)
The unit detects the Scale
Build-up in the Heat
Exchanger many times
(The unit is locked.)
The unit is locked because of repeated Scale Build-up error codes.
Must flush the Heat Exchanger to remove the Scale Build-up.
Before flushing the Heat Exchanger, contact Noritz America
for more information.(866-766-7489)
The outlet temperature is
colder than set temperature.
Contact the nearest Noritz agent.
The indication on the display window shown is not an error of unit.
If you try to supply a low flow of water when the inlet water temperature
is high, hot water is not supplied sometimes (combustion is automatically
stopped and the temperature of outlet water does not become hot).
Display Window
#
=1-9,
A, b, C, d, E, F
=1-4, F
# =1-9,
A, b, C, d, E, F