![Noritz NH-1501-DV Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/noritz/nh-1501-dv/nh-1501-dv_installation-and-instruction-manual_1705061005.webp)
5
Be sure to do
Prohibited
Prohibited
• Avoid installation above gas ranges or stoves.
• Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installa-
tion location, take measures to prevent the fumes and steam
from entering in the equipment.
• Install in a location where the exhaust gas flow will not be
affected by fans or range hoods.
• Take care that noise and exhaust gas will not affect neigh-
bors.
• Before installing, make sure that the exhaust flue termination
will have the proper clearances according to the National Fuel
Gas Code (ANSI Z223.1).
• Installation must conform with local codes, or in the absence
of local codes, the National Fuel Gas Code, ANSI Z223.1/
NFPA 54- latest edition and/or CSA B149.1, Natural Gas and
Propane Installation Code (NSCNGPIC).
State of California: The boiler must be braced, anchored or strapped to avoid moving during an earth-
quake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request
instructions.
For Venting Manufacturers Requirements, see websites or phone numbers listed below:
Noritz N-Vent
www.noritz.com
Protech FastNSeal & W2
www.protechinfo.com
HeatFab SafTVent
www.heat-fab.com
Z-Flex Z-Vent
www.z-flex.com
Flex-L StaR-34
1-800-561-1980
CAUTION
Содержание NH-1501-DV
Страница 31: ...31 ...