![Noritz NC250-DV-ASME Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/noritz/nc250-dv-asme/nc250-dv-asme_owners-manual_1705208024.webp)
24
Troubleshooting-3
The hot water is turbid.
• This is harmless. Small bubbles appear as the air in the
water is heated and depressurized rapidly to
atmospheric pressure.
The water appears blue
The bath tub/wash-basin has turned
blue
• Coloration to a blue color may be noticed from small
traces of copper ion contained in the water and fat
(furring). However, there are not problems concerning
health. Coloration of the bath tub/wash-basin can be
prevented by cleaning frequently.
(Continued)
Water leaks from the drain plugs
on the outlet.
• When the unit is under very high pressure, water will leak
from the drain plugs as a safety so that the unit is not
damaged by the high pressure.
åÃè·ï\é¶Ç Ç®í
≤
Ç
◊
Ç
≠
ÇæÇ
≥
Ç¢
åÃè·ï\é¶Ç Ç®í
≤
Ç
◊
Ç
≠
ÇæÇ
≥
Ç¢
Water Quality
Damage to the water heater as a result
of poor water quality is not covered by
the Limited Warranty. To ensure full
warranty coverage, treat or condition
water that exceeds the target levels
provided in this table.
Source: EPA National Secondary Drinking Water
Regulations (40 CFR Part 143.3)
Total Hardness*
: 200 mg/L (12 gpg) or less
Aluminum
: 0.05 to 0.2 mg/L or less
Chloride
: 250 mg/L or less
Copper
: 1 mg/L or less
Iron
: 0.3 mg/L or less
Manganese
: 0.05mg/L or less
pH
: 6.5 - 8.5
Total Dissolved Solids
: 500 mg/L or less
Zinc
: 5 mg/L or less
Sulfate ion
: 250 mg/L or less
Residual chlorine
: 4 mg/L or less
* Maximum limit suggested by Noritz.