![Noritz GQ-C3259WZ-FF US Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/noritz/gq-c3259wz-ff-us/gq-c3259wz-ff-us_owners-manual_1705158046.webp)
46
Specifications
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water pressure,
water supply, piping conditions, and water temperature.
Specification
Indoor / Outdoor Wall mounted
Direct Ignition
15-150 psi
(Recommended 30 psi or more for maximum performance)
0.5 GPM (2.0 L/min)
0.29GPM (1.1 L/min)
27.0” (687mm) × 18.5” (471mm) × 12.8” (325mm)
81 lbs.
0.74 Gallon(2.8L)
NPT 3/4"
NPT 3/4”
NPT 3/4”
NPT 1/2”
120 VAC (60Hz)
NG : 100W LP : 90W
Freeze Prevention 167W
Front Cover, Side/Top Plate : Hot-dipped zinc-aluminum-
magnesium-alloy-coated steel w/ Polyester Coating
Back Plate : Hot-dipped zinc-aluminum-magnesium-
alloy-coated steel w/o Coating
Bottom Plate : Zincified Steel Plate/Polyester Coating
PP
Stainless Steel : 316L
Stainless Steel : 316L
Flame Rod, High Limit Switch,
Lightning Protection Device (ZNR),
Freezing Prevention Device, Fan Rotation Detector
Remote Controller, Remote Controller Cord, Anchoring Screws,
Drain hose (With clamp) , Wall Mounting Bracket
Specifications
Performance
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Activation Flow Rate*
Minimum Operating Flow Rate*
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Accessories
* Specifications may be changed without prior notice.
* The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water temperature.
* Minimum operating flow rate may change by setting temperature and water temperature.
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Condensate Drain
Safety Devices
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
NG
LP
45°F (25°C) Rise
Maximum Performance
199,900 btuh
199,900 btuh
Minimum Performance
18,000 btuh
18,000 btuh
8.7 GPM (33 L/min.)
0.5-11.1 GPM (2-42 L/min.)
100-150°F (In 5°F intervals),
160, 170, 185°F (14 Options)
Casing
Flue Collar
Primary Heat Exchanger
Secondary Heat Exchanger
Supply
Consumption
°F Mode:
°C Mode:
37-48°C (In 1°C intervals),
50-85°C (In 5°C intervals) (20 Options)
Power Vented
NCC199CDV (GQ-C3259WZ-FF US)
Содержание GQ-C3259WZ-FF US