![Noritz GQ-2857WX US Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/noritz/gq-2857wx-us/gq-2857wx-us_owners-manual_1705148019.webp)
19
Drain Plugs
E a c h d r a i n p l u g
mignt not be visible if
insulation is installed
around the piping.
If the water heater will not be used for a long period of time, drain the water.
Drain the water as follows:
To avoid burns, wait until the equipment cools down
before draining the water. The appliance will remain
hot after it is turned off.
High Temperature
CAUTION
Fully open all hot water fixtures.
4
Open all drain plugs and drain the water out of
the unit.
1
Close the water supply
valve.
6
Close the gas valve and disconnect
the electrical power supplied to the unit.
2
3
Fully open all
hot water fixtures.
Drainage Using the Remote Controller
2
(1) Turn the power on/off button “On”.
(2) Turn and leave open the
hot water fixtures for more
than 2 minutes and close.
* If multiple units are being used,
drain two minutes for each unit.
* An 11 Error Code may appear on
the remote controller.
This is not a malfunction of the unit.
Do not turn Power ON/OFF Button OFF.
Manual Draining
Close the water supply
valve and disconnect
the electrical power
supplied to the unit.
3
4
5
When the water is completely drained, replace
all drain plugs and close the hot water fixtures.
5
Open all drain plugs and drain the
water out of the unit.
6
Close the gas valve.
1
When the water is completely drained,
replace all drain plugs and close the
hot water fixtures.
Fixture
Fixture
(Ex. 120°F)
Do not touch with wet hands.
Do not touch with wet hands.
Drain water into a bucket to prevent water damage.
(1) Turn the power on/off
button “off”.
(2)
Press the flow meter alarm set
button for about two seconds
until the alarm sounds.
The maximum hot water
temperature will flash.
(3) Press the flow meter alarm
set button again.
(4) Press the setting button
marked “ “. The display
will change from "oF" to "on"
after the button is pushed.
Turning the Unit Back On
1. Check that all drain plugs are inserted.
2. Check that all hot water fixtures are closed.
3. Follow the procedure on p.11 “Initial operation”, steps 1 through 4.
Preventing Damage from Freezing-2
To prevent damage from freezing, the water heater must be plugged into power at all times. If power is unplugged, drain the
water completely from the water heater. Then use an air compressor to remove all water from inside the unit's water piping.
It is recommended that Isolation Valves are installed on the water heater, otherwise the water connections will need to be
removed to drain the unit completely. Freeze damage due to not draining properly will not be covered under warranty.
Fixture
Содержание GQ-2857WX US
Страница 32: ......