Water Treatment
This water heater is equipped with an optional automatic service reminder function to alert the user
when
flushing
or a
cartridge/filte
r
change
is required. Once activated, the unit will display an "05" error
code on the remote controller when maintenance is due. The service interval can be set for either 6,
12, or 24 months; refer to
page
28 for recommended
flushing
intervals. If a water treatment device is
installed, refer to the instructions provided with the device for
suggested
service intervals. By default,
the service reminder function is disabled.
To activate or adjust the service reminder error "05", refer to the below procedures.
Note: The
setting
must be done within the
first
10 minutes of
connecting
electrical power to the water
heater.
Setting Procedure:
1. Turn the water heater of
f by pressing the Power On/O
ff Button on the remote controller.
2. Disconnect, then reconnect electrical power to the water heater.
3.
Pres
s
Setting
Button " " or " " within 10 minutes of
connecting
electrical power until the remote
controller displays "99".
4. Press Setting Button " " or " " until the remote contr
oller
displays "2C".
5. Press the Flow Meter
Alarm Set Button for more than
0.5 seconds to switch between ON and OFF
.
"oF" PRIORIT
Y
LED goes out
"on" PRIORIT
Y LED blinks
6. If "2D" also needs to be changed, repeat steps 4 and 5.
7. T
o confirm the settings, press the Setting Buttons " " and "
" simultaneously for more than
5 seconds.
After the settings are confirmed, the maintenance writer mode wi
ll end and the remote
controller display will disappear.
ON=
OFF
=
No warnin
g
2D
2C
6 months
12 months
24 months
*Initial factory setting.
Reset the display of the operation panel in the following way a
fter the water heater is serviced.
When the "05" error code appears, reset the display only aft
er the water heater is flushed and/or
the water treatment device is serviced.
If the error is reset without performing the necessary servi
ce, the water heater may fail prematurely.
Note : In the case of Quick connect multi system, perform sc
ale cleaning of both units.
1. Set the Power On/O
f
f Button to the OFF position.
2. Push the Flow Meter
Alarm Set Button more than 2 seconds.
3. Push the Flow Mete
r
Alarm Set Button several times until "7 oF" is displayed.
4. Press Setting Button
"
▲
"
more than 5 seconds.
This will complete the service warning reset.
5. Push the Power On/O
ff Button.
6. The preset temperature is displayed.
How to reset the scale warning:
Press setting button "▲" more than
5 seconds. At this time, a sound is
emitted from the operation panel.
Push the Power On/O
ff Button.
Setting Button
Flow Meter
Alarm Set Button
Power On/O
ff Button
<NRC98(-DV,-OD), NRC83(-DV,-OD), NR83-DVC>
32