(1)  Open a hot water fixture and confirm that the Burner On lamp comes on, and that hot water is 

being produced. (If necessary, repeat until the air in the gas piping is bled out).

*  White smoke may be noticed from the exhaust vent during cold weather. However, this is not a 

malfunction of the unit.

*  If an “11” error code appears on the Display Window, close a hot water fixture and then back 

on again, and then open a hot water fixture again.

(2)  Using the optional remote controller, change the temperature setting on the remote controller and 

check that the water temperature changes.

•  If the water heater does not operate normally, refer to “Troubleshooting” in the Owner’s Guide.

*  After the trial operation, clean the filter in the cold water inlet.

12.

 

Maintenance

Periodically check the following to ensure proper

operation of the water heater.

•  The venting system must be examined periodically by a qualified service technician to check for 

any leaks or corrosion.

•  The burner flame must be checked periodically for a proper blue color and consistency. 
•  If the flame does not appear normal, the burner may need to be cleaned.
•  If the burner needs to be cleaned, it must be performed by a qualified service technician.
•  Do not obstruct the flow of combustion and ventilation air.

•  The pressure relief valve must be operated once a year to ensure that it is functioning properly and 

there is no obstruction. Turn the power off to the unit before opening the relief valve, and make sure 

that water draining out of the valve will not cause any damage.

•  If the relief valve discharges periodically, it may be due to thermal expansion in a closed water system. 

Contact the water supplier or a local plumbing inspector on how to correct this situation. 

  Do not plug the relief valve.
•  See Operation Manual for further maintenance.

Warning: 

There is a scald potential if the output temperature is set too high.

 

Should overheating occur, or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

 

Do not use this appliance if any part has been under water. Immediately call a qualified service  technician 

to inspect the appliance and to replace any part of the control system and any gas control which has 

been under water.

 

Periodically check and clean the filter inside the cold water inlet of the unit.

13.

 

Trial Operation

The installer should test operate the unit, explain to

the customer how to use the unit, and give the Owner’s 

Guide before leaving the installation.

•  Preparation ........... (1)  Open a hot water fixture to confirm that water is available, and then close 

the fixture.

   

(2)  Open the gas supply valve.

   

(3)  Turn on the power supply. 

   

 

Using the optional remote controller, turn on the Power On/Off button (the 

Operation lamp will turn on).

Handling after trial operation

•  If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of  

the water out of the unit and the plumbing system to prevent the unit and system from freezing, 

and bleed the gas out of the gas line.

  Freezing is not covered by the warranty.

CAUTION

Содержание ecoTOUGH NRC661-OD-LP

Страница 1: ...y and follow the in stallation instructions Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty Check that the installation was done p...

Страница 2: ...d below are not included with the units but may be necessary for installation Cross Recessed Head Screw Q ty Shape Part Part Shape Q ty 1 Remote Controller Cord 26ft 8m 1 Isolation Valves includes pre...

Страница 3: ...the water supply as unexpected accidents may occur as a result Check Water Supply Quality If the water supply is in excess of 12 grains per gallon 200 mg L of hardness acidic or otherwise impure trea...

Страница 4: ...e surrounding trees and animals The heat and moisture from the water heater may cause discoloration of walls and resinous materials or corrosion of aluminum materials Do not locate the vent terminatio...

Страница 5: ...nstall the unit such as the wall of the second floor where the unit is out of reach When installing the unit in a common side corridor provide a clearance of 47 1 190mm or more in front of the unit Se...

Страница 6: ...rance to service regulator vent outlet J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance K Clearance to a mechanical air supply inlet L Clear...

Страница 7: ...o not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level Locati...

Страница 8: ...er heater as with any gas appliance is the sole responsibility of the installer The installer must be professionally trained to do such work and must always follow all local and national codes and reg...

Страница 9: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Страница 10: ...Btuh NRC661A OD series 120 000 Btuh Table 2 For 8 WC 10 5 WC initial supply pressure Maximum Natural Gas Delivery Capacity 3 0 Pressure Drop Values in Table are in Cubic Feet of Gas per Hour 0 60 Spec...

Страница 11: ...all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION Pipe Size Leng...

Страница 12: ...upply potable water may not be connected to any heating system or components previ ously used with a nonpotable water heating appliance When water is required in one part of the system at a higher tem...

Страница 13: ...r on the inlet If this is not done local boiling will occur inside the water heater causing abnormal sounds and decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented...

Страница 14: ...ng and form If this water heater will be installed in an application where the supply water is hard the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener Refer to...

Страница 15: ...15 the Heat Exchanger must be flushed is set to Flushing Mode from an authorized Noritz wholesaler...

Страница 16: ...16 located...

Страница 17: ...nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 0 8 GPH from the water heater Horizontal runs must be slo...

Страница 18: ...n of piping and form Condensate piping to floor drain Condensate piping with pump Slope pipe downwards 1 4 per foot or more The end of the drain pipe must have an air gap 1 or more USE NON CORROSIVE M...

Страница 19: ...include an integrated shut off and service valve with unions and a pressure relief valve Notes 1 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated sh...

Страница 20: ...The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 182W Use an appropriate circuit Do not disconnect the power supply when not in use When the po...

Страница 21: ...er heater back into operation press the Power On Off Button on the optional remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display When changing t...

Страница 22: ...On Off Button Flow Meter Alarm Set buttton Setting Button Remote Controller Setting Procedure 1 Turn the water heater off by pressing the Power On Off Button on the remote controller 2 Disconnect the...

Страница 23: ...efore opening the relief valve and make sure that water draining out of the valve will not cause any damage If the relief valve discharges periodically it may be due to thermal expansion in a closed w...

Страница 24: ...s stop and follow the instructions on page 3 of Owner s Guide 6 Turn the gas control manual valve counterclockwise to the on position 7 Turn on electric power to the unit 8 The unit will now operate w...

Страница 25: ...90mm 3 0 3 0 6 6 5 16 5mm OBLONG HOLE 4 0 5 13mm WATER DRAIN VALVE HOT WATER OUTLET CONDENSATE DRAIN WATER DRAIN VALVE COLD WATER INLET WIRING THROUGHWAY GAS INLET AC120V WATER DRAIN VALVE WATER FILT...

Страница 26: ...Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locations where special chemi...

Страница 27: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Страница 28: ...he wall pipe containing the remote controller wires through the hole 4 Slide the junction box packing and the junction box over the remote controller wires and wall pipe protruding from the outside wa...

Отзывы: