Noritz cCS-V Скачать руководство пользователя страница 4

4

2. Symbols used in this document

Warning 

If these safety instructions are not observed, it may result in 

personal injury.
If these safety instructions are not observed, it may result in 

malfunction or damage to the equipment.
Notes or instructions that make the job easier and ensure 

safe operation.

3. Product introduction

3.1 Introduction

All Noritz Crossover Valves are carefully inspected and tested before 

e. For maximum 

performance and reliability, please follow the instructions in this manual.

Warning 

This is not an anti-scald device. After installation, you may 

the valve is installed. Once the cold water line is opened, the 

warm water will dissipate in a very short time.
Warning 

For indoor potable water use only.

A Noritz Crossover Valve is designed to bring hot water in an instant to the hot 

water faucets in your home.
Since the system utilizes the existing cold water return line in the home, no 

separate new return line is required. No electricity is required under the sink.
The Noritz Crossover Valve installs at the furthest faucet.

circulation 

pump, through the hot water supply line, and then back to the water heater 

through the existing cold water return line.

Caution

Note

Содержание cCS-V

Страница 1: ...SKU cCS V INSTRUCTIONS Crossover Valve Kit Hot water recirculation valve Installation and operating instructions...

Страница 2: ...cepted codes of good practice For programing please refer to the water heater s installation manual for additional set up information 1 Limited warranty 3 2 Symbols used in this document 4 3 Product i...

Страница 3: ...tain service under this warranty the defective product must be returned to the distributor or dealer of Noritz products from which it was purchased together with proof of purchase and installation dat...

Страница 4: ...nual Warning This is not an anti scald device After installation you may the valve is installed Once the cold water line is opened the warm water will dissipate in a very short time Warning For indoor...

Страница 5: ...available 4 Installation Warning on the valve threads Warning turn with wrench can result in valve damage causing valve to leak and or localized water damage Warning When making piping connections be...

Страница 6: ...er 4 2 Disconnecting the risers 1 Close both the hot and cold water angle stop valves below the sink 2 Fig 1 Close hot and cold water angle stop valves under the sink before installing the thermal byp...

Страница 7: ...ort on the crossover valve 6 7 Open both hot and cold water angle stop valves Check for leaks 8 Crossover valve may be mounted to the wall with screws if 9 For troubleshooting see section Mounting har...

Страница 8: ...ardware not included 1 2 x 3 8 1 2 x 3 8 Hot water IN Cold water IN Crossover valve Hot water OUT Cold water OUT 1 2 x 3 8 1 2 x 3 8 To hot water faucet To cold water faucet Correct Incorrect crossove...

Страница 9: ...temp 170 F 76 C System installation type Open residential potable Max working pressure 145 psi 10 bar Max liquid temperature 140 F 60 C Min liquid temperature 36 F 2 C Connections 1 2 NPSM 5 1 Approv...

Страница 10: ...review crossover valve installation instructions If necessary reinstall crossover valve For installation procedure see section 4 Installation 7 Disposal This product or parts of it must be disposed of...

Страница 11: ...11...

Страница 12: ...12 99675079...