Nordyne R4GD 024K045 Скачать руководство пользователя страница 11

11

Table 3.  Airflow Data.

* Denotes Factory Set Cooling Speed

** Denotes Factory Set Heating Speed

† Can be C or X

CF

M

R

is

e

C

F

M

Ri

s

e

CF

M

R

is

e

C

F

M

Ri

s

e

CF

M

R

is

e

C

F

M

Ri

s

e

C

F

M

R

is

e

C

F

M

R

is

e

T1

84

5

38

73

5

44

625

52

540

60

453

72

33

5

--

21

7

--

20

7

--

* T2

90

5

36

83

0

39

750

43

690

47

635

51

57

5

56

51

5

--

49

5

--

**

 T3

95

0

34

88

0

37

810

40

755

43

705

46

65

5

49

60

0

54

57

0

57

T4

111

0

--

106

5

30

10

20

32

965

34

910

36

86

5

37

82

5

39

79

0

41

T5

126

0

--

121

5

--

11

75

--

11

25

--

10

75

30

1

030

31

99

0

33

96

0

34

T1

84

5

61

73

5

--

625

--

540

--

453

--

33

5

--

21

7

--

20

7

--

* T2

90

5

57

83

0

62

750

69

690

--

635

--

57

5

--

51

5

--

49

5

--

**

 T3

95

0

55

88

0

59

810

64

755

69

705

--

65

5

--

60

0

--

57

0

--

T4

111

0

47

106

5

49

1,

02

0

51

965

54

910

57

86

5

60

82

5

63

79

0

66

T5

126

0

41

121

5

43

1,

17

5

44

11

25

46

10

75

48

1

030

50

99

0

52

96

0

54

T1

84

5

38

73

5

44

625

52

540

60

453

72

33

5

--

21

7

--

20

7

--

T2

90

5

36

83

0

39

750

43

690

47

635

51

57

5

56

51

5

--

49

5

--

**

 T3

95

0

34

88

0

37

810

40

755

43

705

46

65

5

49

60

0

54

57

0

57

* T4

111

0

--

106

5

30

1,

02

0

32

965

34

910

36

86

5

37

82

5

39

79

0

41

T5

126

0

--

121

5

--

1,

17

5

--

11

25

--

10

75

30

1

030

31

99

0

33

96

0

34

T1

84

5

61

73

5

--

625

--

540

--

453

--

33

5

--

21

7

--

20

7

--

T2

90

5

57

83

0

62

750

69

690

--

635

--

57

5

--

51

5

--

49

5

--

**

 T3

95

0

55

88

0

59

810

64

755

69

705

--

65

5

--

60

0

--

57

0

--

* T4

111

0

47

106

5

49

1,

02

0

51

965

54

910

57

86

5

60

82

5

63

79

0

66

T5

126

0

41

121

5

43

1,

17

5

44

11

25

46

10

75

48

1

030

50

99

0

52

96

0

54

T1

95

0

55

88

0

59

810

64

755

69

705

--

65

5

--

60

0

--

57

0

--

T2

111

0

47

106

5

49

10

20

51

965

54

910

57

86

5

60

82

5

63

79

0

66

T3

122

0

43

118

0

44

11

35

46

10

85

48

10

30

50

99

0

52

94

5

55

91

5

57

**

 T4

126

0

41

121

5

43

11

75

44

11

25

46

10

75

48

1

030

50

99

0

52

96

0

54

* T5

134

5

--

130

0

40

12

50

41

12

10

43

11

70

44

1

120

46

1

070

48

1

030

50

T1

95

0

73

88

0

--

810

--

755

--

705

--

65

5

--

60

0

--

57

0

--

T2

111

0

63

106

5

65

10

20

68

965

72

910

--

86

5

--

82

5

--

79

0

--

T3

122

0

57

118

0

59

11

35

61

10

85

64

10

30

67

99

0

70

94

5

73

91

5

--

**

 T4

126

0

55

121

5

57

11

75

59

11

25

62

10

75

65

1

030

67

99

0

70

96

0

72

* T5

134

5

52

130

0

53

12

50

56

12

10

57

11

70

59

1

120

62

1

070

65

1

030

67

T1

102

0

51

94

0

55

860

60

800

65

740

70

68

0

--

61

5

--

57

0

--

T2

118

5

44

111

0

47

10

35

50

980

53

925

56

87

5

59

82

0

63

78

5

66

* T3

141

0

37

133

0

39

12

50

41

11

95

43

11

40

45

1

085

48

1

030

50

97

5

53

**

 T4

152

5

--

145

0

--

13

70

--

13

20

--

12

70

41

1

210

43

1

150

45

1

100

47

T5

165

0

--

158

5

--

15

20

--

14

65

--

14

05

--

1

340

--

1

280

41

1

235

42

T1

102

0

68

94

0

74

860

--

800

--

740

--

68

0

--

61

5

--

57

0

--

T2

118

5

59

111

0

63

10

35

67

980

--

925

--

87

5

--

82

0

--

78

5

--

* T3

141

0

49

133

0

52

12

50

56

11

95

58

11

40

61

1

085

64

1

030

67

97

5

71

**

 T4

152

5

46

145

0

48

13

70

51

13

20

53

12

70

55

1

210

57

1

150

60

1

100

63

T5

165

0

--

158

5

--

15

20

46

14

65

47

14

05

49

1

340

52

1

280

54

1

235

56

T1

118

5

59

111

0

63

10

35

67

980

71

925

75

87

5

--

82

0

--

78

5

--

T2

141

0

49

133

0

52

12

50

56

11

95

58

11

40

61

1

085

64

1

030

67

97

5

71

T3

152

5

46

145

0

48

13

70

51

13

20

53

12

70

55

1

210

57

1

150

60

1

100

63

* T4

165

0

--

158

5

--

15

20

46

14

65

47

14

05

49

1

340

52

1

280

54

1

235

56

**

 T5

177

5

--

171

5

--

16

50

--

16

00

--

15

40

45

1

460

48

1

375

51

1

330

52

T1

118

5

73

111

0

--

10

35

--

980

--

925

--

87

5

--

82

0

--

78

5

--

T2

141

0

62

133

0

65

12

50

70

11

95

73

11

40

--

1

085

--

1

030

--

97

5

--

T3

152

5

57

145

0

60

13

70

64

13

20

66

12

70

69

1

210

72

1

150

--

1

100

--

* T4

165

0

53

158

5

55

15

20

57

14

65

59

14

05

62

1

340

65

1

280

68

1

235

70

**

 T5

177

5

49

171

5

51

16

50

53

16

00

54

15

40

57

1

460

60

1

375

63

1

330

65

T1

118

5

59

111

0

63

10

35

67

980

71

925

75

87

5

--

82

0

--

78

5

--

T2

152

5

46

145

0

48

13

70

51

13

20

53

12

70

55

1

210

57

1

150

60

1

100

63

T3

162

5

--

156

0

45

14

90

47

14

35

48

13

80

50

1

315

53

1

255

55

1

210

57

* T4

172

5

--

166

0

--

16

00

--

15

45

45

14

85

47

1

415

49

1

340

52

1

300

53

**

 T5

177

5

--

171

5

--

16

50

--

16

00

--

15

40

45

1

460

48

1

375

51

1

330

52

T1

118

5

73

111

0

--

10

35

--

980

--

925

--

87

5

--

82

0

--

78

5

--

T2

152

5

57

145

0

60

13

70

64

13

20

66

12

70

69

1

210

72

1

150

--

1

100

--

T3

162

5

54

156

0

56

14

90

58

14

35

61

13

80

63

1

315

66

1

255

69

1

210

72

* T4

172

5

50

166

0

52

16

00

54

15

45

56

14

85

59

1

415

62

1

340

65

1

300

67

**

 T5

177

5

49

171

5

51

16

50

53

16

00

54

15

40

57

1

460

60

1

375

63

1

330

65

1/

2

35,

000

30-

60

2

8

,000

1

0

 X

 1

0

23

,0

0

0

10

 X 

10

1

/2

23

,0

0

0

10

 X 

10

1

/2

0.

5

0

.6

0.

7

0

.8

E

x

te

rn

al

 S

ta

ti

c

 P

ressu

re

 (

In

c

h

e

s

 W

a

ter

 C

o

lu

m

n

)

C

ool

ing 

Ou

tp

u

(B

TUh)

Mot

o

Ta

p

Bl

o

w

e

Si

z

e

Mot

o

HP

0

.1

0

.2

0

.3

0

.4

30K

045

(†)

4

5

,0

00

H

e

a

ti

ng 

O

u

tput

 

(B

T

U

h

)

He

a

ti

n

g

 

Ri

s

e

 

R

a

ng

e

(F)

24K

045

(†)

4

5

,0

00

35,

000

30-

60

Mode

Nu

m

b

e

(*

)R

4

G

D

-

H

eat

in

g

 

In

put

 

(B

T

U

h

)

24K

072

(†)

7

2

,0

00

56,

000

40-

70

30K

072

(†)

7

2

,0

00

56,

000

40-

70

75,

000

45-

75

42K

096

(†)

9

6

,0

00

75,

000

45-

75

36K

096

(†)

9

6

,0

00

48K

120

(†)

120,

00

0

94,

000

45-

75

28

,0

0

0

10

 X 

10

1

/2

36K

072

(†)

7

2

,0

00

56,

000

40-

70

3

5

,000

1

0

 X

 1

0

1/

2

35

,0

0

0

10

 X 

10

1

/2

42K

072

(†)

7

2

,0

00

56,

000

40-

70

4

0

,000

1

0

 X

 1

0

3/

4

40

,0

0

0

10

 X 

10

3

/4

48K

096

(†)

9

6

,0

00

75,

000

45-

75

4

6

,000

1

0

 X

 1

0

3/

4

46

,0

0

0

10

 X 

10

3

/4

60K

096

(†)

9

6

,0

00

75,

000

45-

75

5

5

,000

1

0

 X

 1

0

3/

4

55

,0

0

0

10

 X 

10

3

/4

60K

120

(†)

120,

00

0

94,

000

45-

75

Содержание R4GD 024K045

Страница 1: ...ncy or the gas suppli er These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance Some local codes require licensed installati...

Страница 2: ...2...

Страница 3: ...neral 14 LineVoltage 14 Electrical Data Table 15 BlowerSpeed 15 RoomThermostat 16 SYSTEM CHECK 16 Pre Start Check List 16 WIRINGDIAGRAMS 18 START UPPROCEDURE 16 AirCirculation 16 Short Cycle Protectio...

Страница 4: ...avebeensecurelypackaged atthepointofshipment Afterunpackingtheunit carefully inspect it for apparent and concealed damage Claims for damage should be filed with the carrier by the consignee Requiremen...

Страница 5: ...upply Entry Low Voltage Entry Gas Supply Entry 16 6 24 6 31 0 2 9 1 8 4 0 12 45 12 45 4 0 55 8 8 75 Horizontal Supply Duct Opening Horizontal Return Duct Opening 4 0 1 75 9 75 24 75 16 0 Condensing Co...

Страница 6: ...39 0 35 3 024K072 435 445 26 0 26 5 39 0 35 3 030K045 430 440 26 5 26 5 39 0 35 3 030K072 440 450 26 0 26 5 39 0 35 3 036K072 470 480 26 5 26 5 39 0 35 3 036K096 485 495 26 0 26 5 39 0 35 3 042K072 50...

Страница 7: ...re being replaced condensation Do not install the unit such that exhaust from the vent termination is directed into window wells stairwells under decks or in alcoves or similarly recessed areas The ve...

Страница 8: ...D E Blower Control Duct Coil Panel A Panel B Panel C End D Top E 024 045 45 000 36 36 1 36 36 024 072 72 000 36 36 1 36 36 030 045 45 000 36 36 1 36 36 030 072 72 000 36 36 1 36 36 036 072 72 000 36...

Страница 9: ...e combustible material on or against the unit cabinet Do not place combustible materials including gasoline and any other flammable vapors and liquids in the vicinity of the unit Figure 4 Condensate D...

Страница 10: ...exposure to contaminated combustion air will result in safety and performance related problems CIRCULATING AIR SUPPLY WARNING Products of combustion must not be allowed to enter the return air ductwor...

Страница 11: ...5 1520 1465 1405 1340 1280 41 1235 42 T1 1020 68 940 74 860 800 740 680 615 570 T2 1185 59 1110 63 1035 67 980 925 875 820 785 T3 1410 49 1330 52 1250 56 1195 58 1140 61 1085 64 1030 67 975 71 T4 1525...

Страница 12: ...truction standard on fibrous glass ducts Fibrous ductwork and internal acoustical lining must be NFPA Class 1 air ducts when tested per UL Standard 181 for Class 1 ducts Horizontal to Down flow Conver...

Страница 13: ...use fire explosion property damage carbon monoxide poisoning personal injury or death GAS AND HIGH ALTITUDE CONVERSIONS Conversion conversion of this unit must be performed by qualified service person...

Страница 14: ...WARNING To avoid the risk of electrical shock personal injury or death disconnect all electrical power to the unit before performing any maintenance or service The unit may have more than one electric...

Страница 15: ...le 7 or on the unit rating label and according to the National Electric Code and applicable local codes Provide power supply or supplies for the unit in accordance with the unit wiring diagram and the...

Страница 16: ...ns at Note Ifthesamespeedisrequiredforbothheatingand cooling remove either the red or orange wire from the blower motor Next obtain the jumper wire from the homeownerspacketandconnectittotheblowerrela...

Страница 17: ...peed Motors Green Gray Black Yellow Blue 1 2 3 4 5 6 7 8 9 R C Y G W X Y1 R G W1 Gas Valve Typical Wiring Field Supplied for 1 Stage Cool 1 Stage Heat Typical Wiring Field Supplied for 2 Stage Cool 1...

Страница 18: ...Low Flame Sensor Signal Continuous Flash Flame Present On 1 1 2 2 FLAME ROLL OUT SWICH LIMIT SWITCH TO THERMOSAT Y2 Y C W1 G R PRESSURE SWITCH GROUND R C Y G W NEUTRALS EAC HUM XFMR L1 EAC COOL HEAT...

Страница 19: ...t must not exceed that on the data label less 4 for each 1 000 ft Follow the procedure below to determine the firing rate 1 Shut off all other gas fired appliances 2 Start the unit in heating mode and...

Страница 20: ...est setting 2 Turn off all electrical power to the appliance if service is to be performed 3 Remove the control access door panel upper door if two door model 4 Move the gas control knob clockwise to...

Страница 21: ...ntrollocatedintheunitcontrolbox Thewiring diagram on the unit and in Figure 10 show the speed taps for adjusting motor speed Refer to the Blower Speed Section of this installation instruction for more...

Страница 22: ...d environmentally responsiblerefrigeranthandlingprocedures WARNING The gas electric units are shipped fully charged and ready for installation When a system is installed according to these instruction...

Страница 23: ...g space can create potentially hazardous conditions including carbon monoxide poisoning that could result in personal injury or death Cleaning of Heat Exchanger If the heat exchanger must be cleaned d...

Страница 24: ...clean them if necessary with a soft wire brush and or the nozzle of a vacuum cleaner BE EXTREMELY CAREFUL NOT TO DAMAGE THE IGNITOR WHILE CLEANING THE BURNER 10 Replaceallthepartsinreverseorderfromwhi...

Страница 25: ...he warm up interval is increased by 3 seconds on the next try And if successful it remains there Min and max warm up time limits are set at 6 and 54 seconds respectively 6 Theflamemustbeproventhrought...

Страница 26: ...______ Has the Owner s Information been reviewed with the homeowner _________________________________ Has the Literature Package been left with the homeowner _________________________________ Minimum...

Страница 27: ...27...

Страница 28: ...Replaces7085310 Specifications and illustrations subject to change without notice and without incurring obligations PrintedinU S A 03 06 O Fallon MO INSTALLER PLEASE LEAVE THESE INSTALLATION INSTRUCT...