12 SEER - Refrigerant Charging Tables for Heating Mode of Operation - Continued
4 Ton
- Shaded Boxes indicate
flooded conditions
* Note: All pressures are listed in psig. and all temperatures in °F.
- Rated Design Values. Suction Pressure will be lower than design value if indoor air
flow, entering dry bulb, or entering wet bulb temperatures are lower than design.
- Discharge temperatures greater than charted
values indicate an undercharged system.
Pressures shown are for heat pump operating only without back-up heat.
OUTDOOR TEMPERATURE (DEG. F)
0
10
20
30
40
Suc.
Disch.
Disch.
Suc.
Disch.
Disch.
Suc.
Disch.
Disch.
Suc.
Disch.
Disch.
Suc.
Disch.
Disch.
Press
Press. Temp.
Press.
Press. Temp.
Press.
Press. Temp.
Press.
Press. Temp.
Press.
Press. Temp.
7
122
121
16
137
123
24
152
125
32
167
126
43
175
144
8
129
119
17
143
121
25
157
123
33
170
124
44
182
141
9
136
117
18
149
119
26
161
121
34
174
122
45
189
138
10
143
115
19
155
117
27
166
119
35
178
120
46
196
136
11
150
113
20
161
115
28
171
117
36
181
118
47
203
133
12
157
111
21
167
113
29
176
115
37
185
116
48
210
130
13
164
109
22
172
111
30
180
113
38
189
114
49
217
127
50
60
Suc.
Disch.
Disch.
Suc.
Disch.
Disch.
Press.
Press. Temp.
Press.
Press. Temp.
57
202
178
71
228
213
58
209
174
72
235
206
59
216
169
73
242
200
60
223
165
74
249
194
61
230
160
75
256
188
62
237
156
76
263
182
63
244
151
77
270
176