INSTALLER INFORMATION

IMPORTANT SAFETY INFORMATION

Please read all instructions before servicing this equipment. 
Pay attention to all safety warnings and any other special 
notes highlighted in the manual. Safety markings are 
used frequently throughout this manual to designate a 
degree or level of seriousness and should not be ignored. 

WARNING

 indicates a potentially hazardous situation that 

if not avoided, could result in personal injury or death. 

CAUTION

 indicates a potentially hazardous situation that 

if not avoided, may result in minor or moderate injury or 
property damage.

 WARNING:

Shut off all electrical power to the unit 
before performing any maintenance or 
service on the system. Failure to comply 
may result in personal injury or death.

 WARNING:

Unless noted otherwise in these 
instructions, only factory authorized parts 
or accessory kits may be used with this 
product. Improper installation, service, 
adjustment, or maintenance may cause 
explosion, fi 

re, electrical shock or other 

hazardous conditions which may result 
in personal injury or property damage

 WARNING:

P5RF units are fully charged with R-410A 
refrigerant and ready for installation. When 
a system is installed according to these 
instructions, no refrigerant charging is 
required. If repairs make it necessary for 
evacuation and charging, it should only be 
attempted by qualifi ed, trained personnel 
thoroughly familiar with this equipment. 
Some local codes require licensed 
installation service personnel to service this 
type of equipment. Under no circumstances 
should the equipment owner attempt to 
install and/or service this equipment. Failure 
to comply with this warning could result in 
equipment damage, personal injury, or death.

 CAUTION:

This unit uses refrigerant R-410A. DO NOT 
use any other refrigerant in this unit. Use 
of another refrigerant will damage the unit.

 WARNING:

The information listed below must be 
followed during the installation, service, 
and operation of this unit. Unqualifi ed 
individuals should not attempt to interpret 
these instructions or install this equipment. 
Failure to follow safety recommendations 
could result in possible damage to the 
equipment, serious per

sonal injury or death.

• The installer must comply with all local codes and 

regulations which govern the installation of this type 
of equipment. Local codes and regulations take 
precedence over any recommendations contained in 
these instructions. Consult local building codes and 
the National Electrical Code (ANSI CI) for special 
installation requirements.

•  All electrical wiring must be completed in accordance 

with local, state and national codes and regulations 
and with the National Electric Code (ANSI/NFPA 70) 
or in Canada the Canadian Electric Code Part 1 CSA 
C.22.1.

•  This equipment contains liquid and gaseous refrigerant 

under high pressure. DO NOT USE ANY PORTION OF 
THE CHARGE FOR PURGING OR LEAK TESTING.
Installation or servicing should only be performed by 
qualifi ed trained personnel thoroughly familiar with 
this type equipment.

•  This unit is designed for outdoor installations only and 

should be located in a position as shown on page 6.

•  Follow all precautions in the literature, on tags, and 

on labels provided with the equipment. Read and 
thoroughly understand the instructions provided with 
the equipment prior to performing the installation and 
operational checkout of the equipment.

Содержание P5RF

Страница 1: ...occurs check the instructions and follow recommendations given If these suggestions don t eliminate your problem call your servicing contractor The Installation Instructions are primarily intended to...

Страница 2: ...2...

Страница 3: ...13 Figures Tables 14 Figure 8 Unit Dimensions 14 Table 4 P5RF Physical Data 14 Refrigerant Charging Charts 15 Figure 10 P5RF X24K 2 Ton Units 15 Figure 11 P5RF X36K 3 Ton Units 15 Figure 12 P5RF X48K...

Страница 4: ...em will not operate regardless of the temperature selector setting Operating the Indoor Blower Continuously Thecontinuousindoorbloweroperationistypicallyusedto circulatetheindoorairtoequalizeatemperat...

Страница 5: ...or service this equipment Failure to comply with this warning could result in equipment damage personal injury or death CAUTION This unit uses refrigerant R 410A DO NOT use any other refrigerant in t...

Страница 6: ...acked at the time of shipment and upon arrival should be carefully inspected for damage prior to installing the equipment at the job site Verify coil fins are straight If necessary comb fins to remove...

Страница 7: ...duct collar so the edge of the unit opening fits between the flange and the bead 2 Overlap the collar ends keeping the small screw holes underneath 3 Align the holes in the crimped area and install on...

Страница 8: ...t into the drain connection until hand tight 2 Connectthecondensatetubingontothefitting forming a trap near the drain connection 3 Route the condensate tube from the trap to a suitable drain NOTE For...

Страница 9: ...conduit is recommended 208 230 Volt units are shipped from the factory wired for 230 volt operation For 208V operation remove the lead from the transformer terminal marked 240V and connect it to the...

Страница 10: ...led accessories The thermostat should be mounted about 5 feet above the floor on an inside wall DO NOT install the thermostat on an outside wall or any other location where its operation may be advers...

Страница 11: ...t or electrical connections The blower must be set to high speed for electric heat operation Refer to Table 3 for blower speeds Blower Speed For optimum system performance and comfort it may be necess...

Страница 12: ...T UP ADJUSTMENTS Pre Start Checklist The following check list should be observed prior to starting the unit Verify the unit is level and allows proper condensate drainage Verify the outdoor coil and t...

Страница 13: ...pment requires certain mechanical skills and tools If you do not possess these skills contact your dealer for maintenance Consult your localdealerabouttheavailabilityofmaintenancecontracts Routine mai...

Страница 14: ...ain Connection 1 12 13 1 38 3 2 3 2 5 29 9 15 9 04 17 50 14 diameter Return Duct Opening 12 diameter Supply Duct Opening 3 0 5 5 1 3 15 A B Back Duct View Side View Figure 8 Unit Dimensions Table 4 P5...

Страница 15: ...emperature F P5RF X24K Charging Chart Cooling Add refrigerant when below curve Remove refrigerant when above curve Figure 10 Charging Chart for 3 ton Units 200 220 240 260 280 300 320 340 360 380 400...

Страница 16: ...quid Temperature F P5RF X48K Charging Chart Cooling Add refrigerant when below curve Remove refrigerant when above curve Figure 12 Charging Chart for 5 ton Units 200 220 240 260 280 300 320 340 360 38...

Страница 17: ...rs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Packaged Air Conditioner Single Phase NOTES 1 Disconnect all power before serv...

Страница 18: ...t avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE WIRING DIAGRAM P...

Страница 19: ...19...

Страница 20: ...nse plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings...

Отзывы: