Figure 5. C8DA Coil Dimensions

2 1/2”

W

19 1/2”

1 3/8”

1”

12 1/8”

14 1/2”

H

Table 1. Coil Specifications

C8DA-

01830

036

042

Nominal Capacity (BTUH)

18,000 - 30,000

36,000

42,000

Nominal Airflow (CFM)

600 - 1,000

1,200

1,400

W - Width (in.)

18 1/8

18 1/8

18 1/8

H - Height (in.)

18

18

24 3/4

Connection - Liquid Line (in.)

3/8

3/8

3/8

Connection - Suction Line (in.)

3/4

3/4

3/4

Installed Orifice Size (in.)

.061

.067

.071

NOTES:

1.  Individual restrictors are available by part number - PN664*** (where *** represents the size). 

Example: 664103 is a restrictor 0.103 in diameter.

2. 

Refer to sales specification sheets for Listed/Certified combinations of equipment and required accessories.

3. 

Refer to the current AHRI directory for certified ratings of split systems.

COIL SPECIFICATIONS & DIMENSIONS

Содержание C8DA Series

Страница 1: ...eciding factor when installing this product and using common sense plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious injury death or property damage These instructions are primarily intended to assist qualified individuals experi...

Страница 2: ...on of this unit Unqualified individuals should not attempt to interpret these instructions or install this equipment If you do not posses mechanical skills or tools call your local dealer forassistance Undernocircumstancesshould the equipment owner attempt to install and or service this equipment Failure to follow safety recommendations could result in possible damage to the equipment serious pers...

Страница 3: ...l COIL INSTALLATION WARNING ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Improper servicing could result in dangerous operation serious injury death or property damage Beforeservicing disconnectallelectricalpower to the furnace and outdoor condensing unit When servicing controls label all wires prior to discon...

Страница 4: ...e distributor body and hand tighten both components Mark a line on both bodies and then tighten an additional 1 4 turn using two wrenches The movement of the two lines will show how much the nut is tightened If a torque wrench is used tighten to 10 12 ft lbs or 14 16 Nm Connecting the Linesets 1 Route and cut both lineset tubes to proper length in accordance with the outdoor unit specifications Ve...

Страница 5: ...mum horizontal slope in the direction of discharge of not less than 1 vertical for every 10 ft of horizontal run During system checkout inspect the drain line and connections to verify proper condensate drainage Maintenance Service WARNING ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Improper servicing could r...

Страница 6: ...nnection Liquid Line in 3 8 3 8 3 8 Connection Suction Line in 3 4 3 4 3 4 Installed Orifice Size in 061 067 071 NOTES 1 Individual restrictors are available by part number PN664 where represents the size Example 664103 is a restrictor 0 103 in diameter 2 Refer to sales specification sheets for Listed Certified combinations of equipment and required accessories 3 Refer to the current AHRI director...

Страница 7: ...7 ...

Страница 8: ...ications illustrations subject to change without notice or incurring obligations O Fallon MO Printed in U S A 02 12 709279A Replaces 7092790 INSTALLER PLEASE LEAVE THESE INSTRUCTIONS WITH THE EQUIPMENT OWNER ...

Отзывы: