2.6.3.13 Alarm Options Read Command
This command returns the current settings of the dispenser alarm options.
Client command and data:
(STX) + 04 + EJ-- + CD + (ETX)
The above text packet in hexadecimal format:
STX
0
4
E
J
space space
C
D
ETX
0x02
0x30
0x34
0x45
0x4A
0x20
0x20
0x43
0x44
0x03
NOTE:
“D0” is the letter “D” followed by the digit “0.”
Return Format:
D0INiIOoILlPOpPLbAEeAOa
A “1” indicates the alarm feature is enabled. A “0” indicates the alarm feature is disabled.
i:
Enable Input Alarm (IN)
o:
Enable Output Of Input Alarm (IO)
l:
Latch the Input Alarm (IL)
p:
Enable Output of the Pressure Alarm (PO)
b:
Latch the Pressure Alarm (PL)
e:
Enable Auto Increment Alarm (AE)
a:
Enable Output of the Auto Increment Alarm (AO)
EXAMPLE:
If Enable Output of the Pressure Alarm (PO) and Latch the Pressure Alarm (PL) are enabled, the text
packet received from the dispenser is: (STX) + 17 + D0IN0IO0IL0PO1PL1 BD + (ETX)
Length of the response text packet:
Decimal 23 or hexadecimal 17
The above text packet in hexadecimal format:
STX
1
7
D
0
I
N
0
I
O
0
I
L
0x02
0x31
0x37
0x44
0x30
0x49
0x4E
0x30
0x49
0x4F
0x30
0x49
0x4C
0
P
O
1
P
L
1
A
E
0
A
O
0
0x30
0x50
0x4F
0x31
0x50
0x4C
0x31
0x41
0x45
0x30
0x41
0x4F
0x30
B
D
ETX
0x42
0x44
0x03
Appendix B — RS‑232 Protocol (continued)
Ultimus V High Precision Fluid Dispenser
73
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.