RV Series Automated Dispensing Systems
71
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
How to Disable Dispensing for Specific Workpieces in an Array
You can use the Step & Repeat Block icon to disable or enable dispensing for specific workpieces in an array.
NOTE:
Use the Step & Repeat commands to create a program that dispenses the same pattern on multiple
workpieces in an array. Refer to “How to Dispense on Multiple Workpieces in an Array” on page 70.
PREREQUISITES
The system is in the CCD Mode.
Multiple workpieces are properly positioned on the fixture plate.
The correct Step & Repeat program for the array on the fixture plate is open.
#
Click
Step
1
• Make sure the Program screen is open.
2
• Click the STEP & REPEAT BLOCK icon.
The Run Block Select window appears.
3
• To disable dispensing for specific workpieces, click the workpiece locations
in the window. Selections turn red when disabled.
- Green: Enabled
- Red: Disabled
• Leave the Run Block Select window open during dispensing.
NOTE:
Refer to “Function of the Icons in the Run Block Select Window”
below for the function of the Run Block Select window icons.
4
• When dispensing is complete, close the Run Block Select window. The
system clears all disabled selections.
Function of the Icons in the Run Block Select Window
Icon
Name
Icon
Function
Refresh
Refreshes the window.
Select
Entity
Selects a group of blocks.
Cancel
Select
Cancels any selections
Toggle
Select
Toggles a selected block between
enabled and disabled.
Run Block
Select
Runs the currently selected and
enabled blocks.