Prodigy Generation II High-Capacity HDLV Pump
19
Part 1092270
−
05
E
2017
Nordson Corporation
Pinch Valve Installation
NOTE:
All pinch valves intended for repeated
contact with food must be thoroughly cleansed prior
to their first use.
1
Turn the pinch valve body around so that the top
end faces you. Insert the pinch valve insertion
tool through the pinch valve body.
NOTE:
After you put the pinch valve into the
insertion tool, pinch flat the flange on the UP end
of the valve.
2
Insert the UP end of the pinch valve into the
pinch valve insertion tool. Pinch the UP end
flange flat and feed the small end of the
flattened flange into the pinch valve body.
3
While keeping the UP end flange pinched flat,
pull on the the insertion tool.
4
Pull the insertion tool through the valve body
until the UP end of the pinch valve and the
insertion tool comes out the top of the pinch
valve body.