Installation
3-9
Part 1074166-02
E
2018 Nordson Corporation
Lamp Start-Up Timing Diagram for
Remote Input Contact Closures
See Figure 3-8. The Off/Reset contact must be
closed for the unit to go to Standby or On. Once
the lamphead is put into the Standby or On mode
the lamphead will remain in that mode until the
Off/Reset contact is opened.
Lamp Off Lamp to Standby Lamp to ON Lamp Off
1
0
1
0
1
0
LAMP ON
STANDBY
OFF/RESET
>100 ms pulse
10 seconds to warm up
8 seconds to stabilize
>100 ms pulse
Lamp Start Up Timing Diagram for Remote Input Contact Closures
Rapid Startup
Use if your system will sit idle in the Standby mode
before moving to the On mode.
1. On the LAMP selector of the host machine (or
master control unit’s lamp selector), press the
Standby button. There will be an approximate
10 second warm-up time for the magnetron
filament.
2. After the 10 seconds the system will go into
standby and remain there indefintely.
NOTE: Do not leave the power supply in the
standby mode for longer than 30 minutes in
an eight-hour period or more than 15% of
the total lamp-on time. Prolonged standby
periods will shorten the magnetron life.
3. Press the On button to enable the UV light.
The light will turn on instantly but will take
approximately 8 seconds to stabilize. After the
8 seconds, the system ready output contact
(TB1) will close.
Standard Startup
Use to go directly through the warm-up to the On
mode.
1. On the LAMP selector of the host machine (or
master control unit’s LAMP selector), press the
LAMP On button.
2. During the next 10 seconds the unit will go
through the warm up cycle before turning to On.
3. After approximately 8 more seconds the unit
has stabilized and the system is ready to run.
The system ready output contact (TB1) will
close.
Содержание MPS306F
Страница 4: ...Table of Contents ii Part 1074166 02 E 2018 Nordson Corporation...
Страница 12: ...Safety 1 8 Part 1074166 02 E 2018 Nordson Corporation...
Страница 16: ...Description 2 4 Part 1074166 02 E 2018 Nordson Corporation...
Страница 40: ...Operation 4 8 Part 1074166 02 E 2018 Nordson Corporation...
Страница 44: ...Maintenance and Repair 5 4 Part 1074166 02 E 2018 Nordson Corporation...
Страница 48: ...Troubleshooting 6 4 Part 1074166 02 E 2018 Nordson Corporation...
Страница 55: ...Specifications 8 3 Part 1074166 02 E 2018 Nordson Corporation NOT USED Figure 8 1 UV Connector Board...
Страница 56: ...Specifications 8 4 Part 1074166 02 E 2018 Nordson Corporation Figure 8 2 IO Wiring...