P/N 317163B
Remove the old material from the unit by running until empty or draining
from the unit.
NOTE:
Before changing the material type, determine whether the old
and new hot melt materials can be mixed.
S
If mixing is possible: Residues of the old material can be flushed out
using the new material.
S
If mixing is not possible: Thoroughly flush the unit with a cleaning
agent recommended by the hot melt material supplier.
NOTE:
Ensure proper disposal of the old hot melt material according to
local regulations.
CAUTION:
Only use a cleaning agent recommended by the hot
melt material supplier. Observe the Material Safety Data Sheet
of the cleaning agent.
Residues of the cleaning agent can be flushed out of the unit by the new
hot melt material before production begins.
NOTE:
Ensure proper disposal of the cleaning agent according to local
regulations.
3. Changing Hot Melt
Material Type
Flushing with a Cleaning Agent