Nordson iDry Series Скачать руководство пользователя страница 27

Nordson iDry

r

 Series Induction Dryers

21

Part 1075452

04

E

 2016 Nordson Corporation

4. Touch the 

LANGUAGE

 button.  The Language Selection screen

appears.  The currently selected language is displayed at the top.

Figure 17 Language Selection Screen

5. Touch a language button to select the desired language.
6. Touch the 

BACK

 button to return to the Navigation screen.

Timer and Ramp Settings

Ramp

 

Mode Power Level Adjustment 

The ramp mode power level is the percentage of total power needed to

reach the setpoint temperature during the ramp time (ramp time is the time

it takes for a can end to travel the length of the dryer).  The ramp mode is

activated every time coil power is turned on.

1. Press the green power button on the operator terminal.
2. The Nordson iDry splash screen appears, then the Auto screen

(Figure 15).

3. Touch the 

MENU

 button in the lower right-hand corner.  The Navigation

screen appears (Figure 16).

4. Touch the 

RAMP/MOTION

 button.  The Timers and Ramp Control

screen appears (Figure 18).  (This screen may be password-protected.)

5. Touch the 

RAMP TIMER

 field to select it, then use the screen keypad to

set the timer to 999 seconds (16.6 minutes).  This prevents the

controller from entering PID mode.

6. Touch the 

ENT

 key to save your setting.

Содержание iDry Series

Страница 1: ...RDSON CORPORATION AMHERST OHIO USA For parts and technical support call the Industrial Coating Systems Customer Support Center at 800 433 9319 or contact your local Nordson representative This documen...

Страница 2: ...son Corporation publication which is protected by copyright Original copyright date 2007 No part of this document may be photocopied reproduced or translated to another language without the prior writ...

Страница 3: ...Change Record i Part 1075452 04 E 2016 Nordson Corporation Change Record Revision Date Change 04 03 16 Ambient Temperature Compensation instructions added...

Страница 4: ...Change Record ii Part 1075452 04 E 2016 Nordson Corporation...

Страница 5: ...and Line Connections 10 Coil and Tube Installation 11 System Wiring 12 Schematics and Wiring Diagrams 12 Power Input 12 External Interlock 14 Connecting the External Interlock 14 Disabling Customer I...

Страница 6: ...e Power Setpoint 32 High and Low Alarms 32 Faults 32 Navigation Screen 33 Ambient Temperature Compensation 34 Ambient Temperature Compensation Setup 34 How to Change the Setpoint Temperature from the...

Страница 7: ...nd high voltage electrical equipment S can safely perform their assigned tasks S are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tas...

Страница 8: ...tem is operating properly to prevent dangerous concentrations of volatile particles or vapors S Keep clear of moving equipment Before adjusting or servicing moving equipment shut off the power supply...

Страница 9: ...materials Shut off power at a disconnect switch first to prevent sparking Allow 10 minutes for all internal energy storage devices to completely discharge S Know where emergency stop buttons shutoff...

Страница 10: ...the line starts heating within the can ends instantly starts Since heat is created directly within the ends there is no thermal inertia When the line stops heating instantly stops This produces a ver...

Страница 11: ...he motion sensor detects can ends moving through the dryer 3 Operator Control Console Contains the operator interface terminal touch screen which contains all operator control functions including warn...

Страница 12: ...power supplied to the coil to eliminate temperature variations due to line voltage fluctuations applied compound weight and can end start temperature A blower in the controller power inverter enclosu...

Страница 13: ...6 Nordson Corporation Coil Tray Coil and Tube Assembly Motion Sensor Thermocouple Feed Direction 0N CH AL Entrance Exit Controller and Power Inverter Enclosure Figure 3 Theory of Operation Coil Windin...

Страница 14: ...vation Altitude Less than 1524 meters 5000 ft Above 5000 ft system must be de rated Contact your Nordson representative Power Supply Requirements 360 415 Vac 50 Hz or 440 480 Vac 60 Hz 3 phase Class J...

Страница 15: ...bvious shipping damage and shortages If you see any damage or shortages notify the shipper and your Nordson representative immediately NOTE A 5 16 inch hex wrench is required to unlock and lock the co...

Страница 16: ...1 meter 39 in of space at the rear of the dryer to remove the access panel for power and interlock connections and repairs S Provide 1 meter 39 in of space in front of the dryer to open the enclosure...

Страница 17: ...d of the coil tray lid Lift the lid to the full up position 3 Remove the screws 1 securing the air heater and exhaust vent to the entrance and exit hubs Move the air heater and exhaust vent away from...

Страница 18: ...end to the common bus bar and all terminations at other end to other common bus bar 1 2 3 4 5 Figure 8 Coil and Tube Installation 1 Air heater and exhaust vent screws 4 on each hub 2 Cushion and hold...

Страница 19: ...r death from electrical shock See Figure 9 Line power is supplied to the system through a 3 4 in 1 9 cm conduit fitting in the lower left hand corner of the dryer exit end NOTE Wire gauge must be copp...

Страница 20: ...Vdc source at 100 mA to power an internal relay coil refer to Note below The external 24 VDC power source is not referenced to the dryer ground The interlock indicates to the dryer system that the pr...

Страница 21: ...contact is off when S The dryer is turned off S Any fault on the operator panel is activated Status Contact Connection Terminal 32 Output Contact output Motion Sensor See Figure 11 The motion sensor...

Страница 22: ...flow from the exhaust vents Return Shipping Instructions Refer to page 9 for lift points Domestic USA 1 Remove the glass coil tube and coil Carefully pack the tube and coil separately 2 Remove the le...

Страница 23: ...locked from the Options screen which is a password protected screen If you do not have access to the screens required for setup contact your Nordson representative Setup normally needs to be performed...

Страница 24: ...oved from production Keyence Motion Sensor Sensitivity Adjustment WARNING Laser radiation Do not look directly into the laser beam or its reflection from can bodies Doing so could result in serious ey...

Страница 25: ...r beam or its reflection from can bodies Doing so could result in serious eye injury The SICK laser sensor focal point is adjustable between 30 60 mm from the sensor face Adjust the distance screw for...

Страница 26: ...language Other languages available are Spanish French and German 1 Press the green power button on the operator terminal to turn on the dryer 2 The Nordson iDry splash screen appears then the Auto sc...

Страница 27: ...during the ramp time ramp time is the time it takes for a can end to travel the length of the dryer The ramp mode is activated every time coil power is turned on 1 Press the green power button on the...

Страница 28: ...ssword protected by default To access this screen you must first enable it from the Options Setup screen Refer to page 28 Figure 19 Manual Mode Screen 9 Run can ends through the dryer at the desired p...

Страница 29: ...ing delays turning off coil power when can end motion stops This prevents control cycling to ramp mode each time the line momentarily stops The factory default setting is 3 seconds Do not set the moti...

Страница 30: ...EXTERNAL INTERLOCK TIMER field and set the desired time with the keypad 3 Touch ENT to save your setting External Interlock Activation The External Interlock must be wired and activated before you can...

Страница 31: ...various metal types Touch the TEMPERATURE OFFSET field and use the keypad to set the desired offset Touch ENT to save your setting Power Limits Power Limit Control Touch the POWER LIMIT button to tog...

Страница 32: ...tional band P heat S Integral I heat S Derivative D heat These parameters make up the PID loop that controls the duty cycle used to regulate the amount of power applied to the induction coil PID setti...

Страница 33: ...Alarm Setpoints If the product temperature increases to the ALARM HIGH SETPOINT or decreases to the ALARM LOW SETPOINT an alarm fault is issued and the dryer will shut down The factory default settin...

Страница 34: ...tton to toggle change access ON or OFF for the following screens and functions The factory default setting for each is listed along with the page number for the instructions for setting each screen s...

Страница 35: ...n disconnect on left side of control enclosure S Emergency Stop switch S Power pushbutton indicator Start S Off pushbutton Stop S Operator Interface Terminal OIT Operator Interface Terminal Emergency...

Страница 36: ...oubleshooting on page 41 to correct the problem 4 Start your production line and run can ends through the dryer The system powers the induction coil and heats the can ends whenever the motion sensor d...

Страница 37: ...etpoint temperature value 5 A numerical keypad will appear Set a new setpoint and touch the ENT button on the keypad to save the setting Manual Mode The dryer can also be operated in Manual mode The M...

Страница 38: ...nd the actual temperature rises above the Alarm High deviation or falls below the Alarm Low deviation the dryer will continue to operate for a preset period of time Temperature Alarm Delay If the actu...

Страница 39: ...ovides access to the system settings auto and manual screens and operator language screen Touching the MENU button on any screen will open this screen NOTE Some screens are password protected If they...

Страница 40: ...p page for ambient compensation Ambient Temperature Compensation Setup 1 From the main Menu Navigation screen select the CONFIG button Password required 2 See Figure 31 Select the AMBIENT TEMP COMPENS...

Страница 41: ...dard iDry Temperature Setup screen will be locked from use Use the Ambient Compensation Setup screen to change setpoint temperature 6 See Figures 33 and 34 Verify that the following screens are automa...

Страница 42: ...MP button from the Auto Run screen See Figure 36 2 Select the ENTER NEW DATA from the Warning screen 3 A Pop up screen will appear Enter password 4 Enter information into the PRODUCT TEMP SETPOINT fie...

Страница 43: ...NOTE A password is required to perform the following procedure 1 To cancel temperature compensation mode select the MENU button to transfer to the Menu Navigation screen Then select the CONFIG ATC but...

Страница 44: ...data can be monitored to compare original presets to current settings 1 Select the MENU button 2 See Figure 38 From Menu screen select the PLC IO button 3 From PLC IO screen select the AMB C DATA But...

Страница 45: ...down the dryer press the OFF pushbutton on the operator panel NOTE While you can stop the dryer by pressing the EMERGENCY STOP button or by switching the main disconnect switch to the OFF position you...

Страница 46: ...for wear and good contact with the can ends Replace the thermocouple as needed Motion Sensor Clean the sensor head lens with a clean soft cloth When the system is not being used cover the lens with t...

Страница 47: ...ipment failure NOTE Use the schematics provided with your system when performing troubleshooting procedures Problem Possible Cause Corrective Action 1 Dryer will not turn on when POWER button is press...

Страница 48: ...ll access panel properly 8 Temperature overshoots on startup Incorrect ramp mode power level adjustment Adjust setting page 21 9 System stays in Ramp Mode Never switches to Run Mode ON Motion timer se...

Страница 49: ...k circuit failure or incorrect product load DISCONNECT AND LOCKOUT POWER BEFORE PROCEEDING Perform diagnostic test on power processing subsystems RF board driver failure 19 EXT INTLK TIMED OUT fault C...

Страница 50: ...Mode To switch to manual mode from the Auto mode screen 1 Touch the MENU button The Navigation screen opens 2 Touch the MAN Manual Control button If enabled the Manual mode screen opens 3 Enter the d...

Страница 51: ...ety switches Disarming diagnostic devices will void the warranty and may cause equipment failure Coil and Coil Tube Replacement The coil and coil tube can be replaced separately They both must be remo...

Страница 52: ...on Coil and Coil Tube Replacement contd 1 7 2 4 3 5 6 8 8 9 Figure 43 Coil and Tube Replacement Air Heater at Entrance End Shown 1 Vent housings 2 Air Heater 3 Screws 4 on each hub 4 Hubs 5 Nylon slot...

Страница 53: ...ub mounting screws and check the tube clearance c Trim away any protruding shim stock 12 Re install the two cushions and screws into the entrance and exit hubs 13 Re install the heater blower and exha...

Страница 54: ...iDryr Series Induction Dryers 48 Part 1075452 04 E 2016 Nordson Corporation Air Filter Replacement See Figure 45 To replace the filter pull it out of the right side of the holder Figure 45 Filter Repl...

Страница 55: ...f plant Serial number and model number of unit Phone and fax number Name of person requesting service Nature of the service call Parts Ordering Information All parts can be ordered through Nordson Cor...

Страница 56: ...8 52 125 60 53 127 40 54 129 20 55 131 00 56 132 80 57 134 60 58 136 40 59 138 20 60 140 00 61 141 80 62 143 60 63 145 40 64 147 20 65 149 00 66 150 80 67 152 60 68 154 40 69 156 20 70 158 00 71 159...

Страница 57: ...This product has been manufactured according to good engineering practice The product specified conforms to the directive and standards described above Certificates TUV EN60204 ISO EN12100 Cert for EU...

Отзывы: