Hot melt application head EP 30
13
P/N 397191B
E
2005 Nordson Corporation
EP 30
Daily Maintenance
Unit part
Activity
Interval
Refer to
Complete application head
Inspect for damage
Daily
Page 13
p
pp
External cleaning
Daily
Page 13
Control modules
Check for leakage
Daily
Page 13
Visual Inspection for External Damage
CAUTION:
When damaged parts pose a risk to the operational safety of
the unit and/or safety of personnel, switch off the unit and have the
damaged parts replaced by qualified personnel. Use only original Nordson
spare parts.
External Cleaning
External cleaning prevents impurities created during production from
causing the unit to malfunction.
Always follow manufacturer’s instructions when using cleaning agents!
1. Heat cold application head electrically or with a hot air fan until the
adhesive is liquid.
2. Thoroughly remove warm adhesive with a cleaning agent and/or a soft
cloth.
3. Remove dust, fluffs, etc. with a vacuum cleaner or a soft, lint-free cloth.
CAUTION:
Do not damage or remove warning labels. Damaged or
removed warning labels must be replaced by new ones.
Inspecting Control Module
If adhesive escapes, the internal O-rings have worn and the control module
must be replaced.