Calibration and Adjustment
5-13
5.12 Initializing the Digital Gauges
The S-920 Dispensing System is equipped with Cooling/Coaxial, Valve and Fluid Pressure Digital Gauges.
To initialize the digital gauge:
1.
Make sure the air pressure to the pressure gauge is OFF by turning the appropriate regulator
knob counterclockwise until it stops. See Figure 1-5 and Figure 1-6.
2.
To configure the gauge, press and hold down the
SET
button for at least 2 seconds
3.
Select the Measuring Unit by pressing the
Up
button or
Down
button until the desired
measuring unit is displayed and then press
SET
.
!
Available units are kPa or MPa (PA), kgf/cm2 (GF), bar (bAr), and psi (PSi).
4.
Verify the Output 1 type is set on the normally open (1no) setting. If it is not displayed, press
the Up or Down button until 1no is displayed and then press
SET
.
"
NOTE
The output function of the digital gauge is not used on your dispensing system.
5.
Verify the Response Time is set at 192 ms. If it is not displayed, press the
Up
or
Down
button
until 192 is displayed.
6.
Verify the Setting Mode is set on the manual setting (nAn). If the manual setting is not
displayed, press the
Up
or
Down
button until nAn is displayed and then press
SET
.
!
The gauge will now be in the pressure-measuring mode.
7.
Zero the gauge by holding down both arrow buttons simultaneously until zeros (00.0) are
displayed on the screen.
8.
Set the pressure to the desired level for your application by turning the knob on the pressure
regulator knob clockwise until the correct pressure is displayed on the screen.
TIP
To ensure accurate pressure measurement, allow the gauge to warm up for 20 to 30
minutes before adjusting pressure level.
35.4
OUT 1
SET
SMC
MPa
PRESSURE
Item Description Item Description
1 LED
Display
4 Set
Button
2
Switch Output Indicator
5
Down Button
3 Up
Button
Figure 5-15 Initializing the Digital Gauge
1
2
3
4
5
Содержание Asymtek Spectrum S-920
Страница 1: ...Spectrum Series S 920 Dispensing System Installation Operations Maintenance Manual P N 7212417 Rev A...
Страница 2: ......
Страница 4: ......
Страница 30: ...1 14 Introduction 1 10 5 Rear View Figure 1 7A Rear View 2 3 4 1 5...
Страница 124: ......
Страница 172: ...7 12 Maintenance Figure 7 7 Lubricating the X Axis Linear Guides Figure 7 8 Lubricating Y Axis Linear Guides...
Страница 185: ...Troubleshooting 8 11 Figure 8 3 FmXP Scale Setup Menu Figure 8 4 Scale Error Message...
Страница 190: ......
Страница 204: ......
Страница 208: ......
Страница 210: ......
Страница 220: ......
Страница 222: ......
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 234: ......