Model A7AA Air Assisted Airless Gun
4
2000 Nordson Corporation
All rights reserved
108 046C
Issued 1/00
Manual 4-20
To avoid a fire or explosion, follow these instructions.
Ground all conductive equipment in the spray area. Use only
grounded air and fluid hoses. Check equipment and workpiece
grounding devices regularly. Resistance to ground must not exceed
one megohm.
Shut down all equipment immediately if you notice static sparking or
arcing. Do not restart the equipment until the cause has been
identified and corrected.
Do not smoke, weld, grind, or use open flames where flammable
materials are being used or stored.
Do not heat materials to temperatures above those recommended by
the manufacturer. Make sure heat monitoring and limiting devices are
working properly.
Provide adequate ventilation to prevent dangerous concentrations of
volatile particles or vapors. Refer to local codes or your material
MSDS for guidance.
Do not disconnect live electrical circuits while working with flammable
materials. Shut off power at a disconnect switch first to prevent
sparking.
Know where emergency stop buttons, shutoff valves, and fire
extinguishers are located. If a fire starts in a spray booth,
immediately shut off the spray system and exhaust fans.
Shut off electrostatic power and ground the charging system before
adjusting, cleaning, or repairing electrostatic equipment.
Clean, maintain, test, and repair equipment according to the
instructions in your equipment documentation.
Use only replacement parts that are designed for use with original
equipment. Contact your Nordson representative for parts
information and advice.
Fire Safety